Literature DB >> 28554549

Utility of DXA for monitoring, technical aspects of DXA BMD measurement and precision testing.

John J Carey1, Miriam F Delaney2.   

Abstract

Monitoring a patient's bone mineral density (BMD) is one of the main reasons for dual-energy X-ray absorptiometry (DXA) referral. It is widely recommended by clinical guidelines, and the accepted standard in practice for managing patients with osteoporosis and other disorders. Clinicians and DXA providers must be familiar with the scientific rationale and procedures involved in measurement science to obtain accurate and reproducible results. Their importance is critical to maximise the value of scan acquisition and interpretation. Scanning individual patients, with different needs and disorders, requires excellence in training, experience, and is more complex than just simply 'measuring BMD'. Over the past 3 decades many studies have validated the importance of monitoring BMD for fracture risk assessment, and for patients on osteoporosis treatment. New DXA features enhance the value of DXA monitoring today. Quality BMD measurement remains an essential component of patient care in osteoporosis and other disorders, playing a critical role in informed decision making for clinicians assessing and managing their patients. In this article we describe some of the technical aspects of measurement and discuss the utility of DXA for monitoring patients in clinical practice.
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  BMD; DXA; Least significant change; Measurement; Monitoring

Mesh:

Year:  2017        PMID: 28554549     DOI: 10.1016/j.bone.2017.05.021

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  3 in total

Review 1.  Dual-energy X-ray absorptiometry bone densitometry in pediatrics: a practical review and update.

Authors:  Hedieh Khalatbari; Larry A Binkovitz; Marguerite T Parisi
Journal:  Pediatr Radiol       Date:  2020-08-28

2.  Anti-Mullerian Hormone as Predictor of Future and Ongoing Bone Loss During the Menopause Transition.

Authors:  Arun S Karlamangla; Albert Shieh; Gail A Greendale; Elaine W Yu; Sherri-Ann M Burnett-Bowie; Patrick M Sluss; Deborah Martin; Anthony Morrison; Joel S Finkelstein
Journal:  J Bone Miner Res       Date:  2022-04-04       Impact factor: 6.390

3.  The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above.

Authors:  Shaanthana Subramaniam; Chin-Yi Chan; Ima Nirwana Soelaiman; Norazlina Mohamed; Norliza Muhammad; Fairus Ahmad; Pei-Yuen Ng; Nor Aini Jamil; Noorazah Abd Aziz; Kok-Yong Chin
Journal:  Diagnostics (Basel)       Date:  2020-03-25
  3 in total