Literature DB >> 28554240

Numerical analysis of thermal impact of intramyocardial capillary blood flow during radiofrequency cardiac ablation.

Juan J Pérez1, Ana González-Suárez1, Enrique Berjano1.   

Abstract

PURPOSE: The thermal effect of the intramyocardial blood perfusion on the size of lesions created by radiofrequency cardiac ablation (RFCA) has not been adequately studied to date. Our objective was to assess the impact of including this phenomenon in RFCA computer modelling in terms of the thermal lesion depth created.
METHODS: A computer model was built and computer simulations were conducted to assess the effect of including the blood perfusion term in the bioheat equation. This term mimics the intramyocardial blood flow (i.e., blood perfusion) in the cardiac wall at the site at which the RFCA is being conducted and hence represents a heat removing mechanism. When considered, blood perfusion rates ranged from 609 to 1719 ml/min/kg. Two electrode design and modes were considered: a non-irrigated electrode with constant temperature mode and an irrigated electrode with constant power mode.
RESULTS: All the depths computed without including the blood perfusion term were larger than those that did include it, regardless of perfusion rate. The differences in lesion depth between ignoring and including blood perfusion increased over time; for a 60 s RFCA they were 0.45 and 1 mm for minimum and maximum perfusion rate, respectively. The differences were more or less independent of blood flow in the cardiac chamber, electrode type and ablation mode.
CONCLUSIONS: The findings suggest that the heat-sink effect of blood perfusion should be taken into account in the case of ablations (>1 minute) such as those conducted in RFCA of the ventricular wall.

Keywords:  Blood perfusion; cardiac ablation; computer model; intramyocardial blood flow; radiofrequency ablation

Mesh:

Year:  2017        PMID: 28554240     DOI: 10.1080/02656736.2017.1336258

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  5 in total

1.  Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?

Authors:  Ana González-Suárez; Juan J Pérez; Enrique Berjano
Journal:  Biomed Eng Online       Date:  2018-04-20       Impact factor: 2.819

2.  In-Silico Modeling to Compare Radiofrequency-Induced Thermal Lesions Created on Myocardium and Thigh Muscle.

Authors:  Juan J Pérez; Enrique Berjano; Ana González-Suárez
Journal:  Bioengineering (Basel)       Date:  2022-07-19

3.  A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber.

Authors:  Mario Gómez-Barea; Tomás García-Sánchez; Antoni Ivorra
Journal:  Sci Rep       Date:  2022-09-27       Impact factor: 4.996

4.  Cavotricuspid isthmus ablation for atrial flutter: Anatomic challenges and troubleshooting.

Authors:  Georgios Christopoulos; Konstantinos C Siontis; Ugur Kucuk; Samuel J Asirvatham
Journal:  HeartRhythm Case Rep       Date:  2020-03-16

5.  Modeling esophageal protection from radiofrequency ablation via a cooling device: an analysis of the effects of ablation power and heart wall dimensions.

Authors:  Marcela Mercado; Lisa Leung; Mark Gallagher; Shailee Shah; Erik Kulstad
Journal:  Biomed Eng Online       Date:  2020-10-12       Impact factor: 2.819

  5 in total