Literature DB >> 28552698

A Novel Approach for Percutaneous Vertebroplasty Based on Preoperative Computed Tomography-Based Three-Dimensional Model Design.

Jian Li1, JiSheng Lin1, JunChuan Xu1, Hai Meng1, Nan Su1, ZiHan Fan1, JinJun Li1, Yong Yang1, Dong Li1, BingQiang Wang1, Qi Fei2.   

Abstract

OBJECTIVE: To describe a new technique for the efficient use of preoperative planning based on preoperative computed tomography-based three-dimensional (3D) model design for percutaneous vertebroplasty (PVP) in a patient with osteoporotic vertebral compression fracture.
METHODS: A 76-year-old woman with acute osteoporotic vertebral compression fracture (L1 level) accepted a novel precise PVP. A 3D model of thoracolumbar vertebrae (T12-L2) based on preoperative computed tomography scanning data and a simulative PVP (via a bilateral transpedicular approach) were built in MIMICS (Materialise Interactive Medical Image Control System) software. With the help of 3 radiopaque markers located at the skin of the back and preoperative digital design by MIMICS, bilateral skin entry points, needles direction including abduction angle and head inclination angle, and needle insertion depth were established.
RESULTS: During surgery, only 1 shot of fluoroscopy was required to confirm the skin entry points. The operation took only about 23 minutes and total patient exposure dose was 4.5 mSv. The intraoperative radiologic results showed that the cement distribution in the L1 vertebra was good without any puncture-related complications. The patient's visual analog scale score improved from 9 points preoperatively to 2 points postoperatively. The patient's preoperative Oswestry Disability Index score was 80 points, which improved to 57.8 points postoperatively.
CONCLUSIONS: The novel precise PVP based on preoperative 3D model design allows 1) visualization of the morphology of the fractured vertebral body, 2) increased precision of puncture with decreasing incidence of puncture-related complications and reduced radiation exposure, and 3) less operation time, decreasing the learning curve of beginners with limited experience.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Materialise Interactive Medical Image Control System; Osteoporotic vertebral compression fracture; Percutaneous vertebroplasty; Three-dimensional model

Mesh:

Year:  2017        PMID: 28552698     DOI: 10.1016/j.wneu.2017.05.087

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  2 in total

1.  Combined Application of Grid Body Surface Locator and Preemptive Analgesia in Daytime Vertebroplasty.

Authors:  Hongwen Gu; Yuhui Zhao; Yanchun Xie; Yongcun Wei; Linyang Li; Di Meng; Hailong Yu
Journal:  Comput Math Methods Med       Date:  2022-07-25       Impact factor: 2.809

2.  Using Materialise's interactive medical image control system to reconstruct a model of a patient with rectal cancer and situs inversus totalis: A case report.

Authors:  Tao Chen; Yu-Tao Que; Yi-Hao Zhang; Fei-Yu Long; Yi Li; Xin Huang; Ya-Nan Wang; Yan-Feng Hu; Jiang Yu; Guo-Xin Li
Journal:  World J Clin Cases       Date:  2020-02-26       Impact factor: 1.337

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.