Literature DB >> 28551135

Rapid ultrasound assisted emulsification micro-solid phase extraction based on molecularly imprinted polymer for HPLC-DAD determination of bisphenol A in aqueous matrices.

Muhammad Nur' Hafiz Rozaini1, Noorfatimah Yahaya2, Bahruddin Saad3, Sazlinda Kamaruzaman4, Nor Suhaila Mohamad Hanapi5.   

Abstract

Molecularly imprinted polymer (MIP) was employed as sorbent in ultrasound assisted emulsification molecularly imprinted polymer micro-solid phase extraction (USAE-MIP-µ-SPE) of bisphenol A (BPA) in water, beverages and the aqueous liquid in canned foods prior to high performance liquid chromatography-diode array detector (HPLC-DAD) analysis. Several effective variables, such as types of emulsification solvent and its volume, types of desorption solvent and its volume, salting out effect, pH of sample solution, mass of sorbent, extraction and desorption time, and sample volume, were optimized comprehensively. Under the optimized USAE-MIP-µ-SPE and HPLC-DAD conditions, the method demonstrated good linearity over the range of 0.5-700μgL-1 with a coefficient determination of R2=0.9973, low limit of detection (0.07μgL-1), good analyte recoveries (82.2-118.9%) and acceptable RSDs (0.7-14.2%, n=3) with enrichment factor of 49. The method was applied to thirty samples of drinking water, mineral water, river water, lake water, as well as beverages and canned foods, the presence of BPA was identified in four samples. The proposed method showed good selectivity and reusability for extraction of BPA, and hence the USAE-MIP-µ-SPE is rapid, simple, cost effective and environmentally friendly.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aqueous matrices; Bisphenol A; High performance liquid chromatography; Molecularly imprinted polymer; Ultrasound assisted emulsification micro-solid phase extraction

Year:  2017        PMID: 28551135     DOI: 10.1016/j.talanta.2017.05.006

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Magnetic nanoparticles assisted dispersive liquid-liquid microextraction of chloramphenicol in water samples.

Authors:  Salwani Md Saad; Nur Afiqah Aling; Mazidatulakmam Miskam; Mardiana Saaid; Nur Nadhirah Mohamad Zain; Sazlinda Kamaruzaman; Muggundha Raoov; Nor Suhaila Mohamad Hanapi; Wan Nazihah Wan Ibrahim; Noorfatimah Yahaya
Journal:  R Soc Open Sci       Date:  2020-04-08       Impact factor: 2.963

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.