Bigaussian Wavefront Model for Normal and Keratoconic Eyes.

Jos J Rozema1, Pablo Rodríguez, Rafael Navarro, Carina Koppen.   

Abstract

PURPOSE: To report bigaussian multivariate wavefront models capable of stochastically generating an unlimited amount of plausible wavefront data for either normal or keratoconic eyes.
METHODS: The models use centroid wavefront data measured previously with an iTrace in 330 healthy right eyes and 122 keratoconic right eyes. These centroids were fitted to an 11th-order Zernike series, followed by principal component analysis to reduce dimensionality and remove correlations. The remaining parameters were then fitted to a sum of two multivariate Gaussian distributions. This fit then forms the core of the stochastic model, which may be used to generate synthetic data. Finally, the agreement between the original and synthetic data was tested using two one-sided t tests.
RESULTS: For normal eyes, the first eigenvectors mostly represent pure Zernike polynomials, with a decreasing degree of purity with increasing order. For keratoconic eyes, eigenvector purity was considerably lower than for normal eyes. Depending on the data set, series of 22 to 29 eigenvectors were found sufficient for accurate wavefront reconstruction (i.e., root-mean-square errors below 0.05 μm). These eigenvectors were then used as a base for the stochastic models. In all models and all Zernike coefficients, the mean of the synthetic data was significantly equal to that of the original data (two one-sided t test, P > .05/75), but the variability of the synthetic data is often significantly lower (F test, P < .05/75).
CONCLUSIONS: This synthetic wavefront model may be safely used in calculations as an alternative to actual measurements should such data not be available.

Entities:  

Mesh:

Year:  2017        PMID: 28538335     DOI: 10.1097/OPX.0000000000001075

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  1 in total

1.  Image quality eigenfunctions for the human eye.

Authors:  Pablo Rodríguez; Rafael Navarro; Jos J Rozema
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.