Accelerated life-test methods and results for implantable electronic devices with adhesive encapsulation.

Xuechen Huang1,2, Petcharat May Denprasert3, Li Zhou4, Adriana Nicholson Vest4, Sam Kohan3, Gerald E Loeb4,3.   

Abstract

We have developed and applied new methods to estimate the functional life of miniature, implantable, wireless electronic devices that rely on non-hermetic, adhesive encapsulants such as epoxy. A comb pattern board with a high density of interdigitated electrodes (IDE) could be used to detect incipient failure from water vapor condensation. Inductive coupling of an RF magnetic field was used to provide DC bias and to detect deterioration of an encapsulated comb pattern. Diodes in the implant converted part of the received energy into DC bias on the comb pattern. The capacitance of the comb pattern forms a resonant circuit with the inductor by which the implant receives power. Any moisture affects both the resonant frequency and the Q-factor of the resonance of the circuitry, which was detected wirelessly by its effects on the coupling between two orthogonal RF coils placed around the device. Various defects were introduced into the comb pattern devices to demonstrate sensitivity to failures and to correlate these signals with visual inspection of failures. Optimized encapsulation procedures were validated in accelerated life tests of both comb patterns and a functional neuromuscular stimulator under development. Strong adhesive bonding between epoxy and electronic circuitry proved to be necessary and sufficient to predict 1 year packaging reliability of 99.97% for the neuromuscular stimulator.

Entities:  

Keywords:  Accelerated life test; Encapsulation; Implantable; Non-hermetic packaging; Wireless

Mesh:

Substances:

Year:  2017        PMID: 28536859     DOI: 10.1007/s10544-017-0189-9

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  2 in total

Review 1.  Evaluation methods for long-term reliability of polymer-based implantable biomedical devices.

Authors:  Dong Hyeon Lee; Chae Hyun Kim; Jiman Youn; Joonsoo Jeong
Journal:  Biomed Eng Lett       Date:  2021-04-15

2.  Apparatus to investigate the insulation impedance and accelerated life-testing of neural interfaces.

Authors:  N Donaldson; C Lamont; A Shah Idil; M Mentink; T Perkins
Journal:  J Neural Eng       Date:  2018-09-04       Impact factor: 5.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.