Abstract
[Purpose] The purpose of the present study was to examine the intrarater reliability and intrarater reliability of lateral scapular slide tests among young females.Entities:
Keywords: Asymmetry of the scapula; Lateral scapular slide test; Reliability
Year: 2017 PMID: 28533618 PMCID: PMC5430281 DOI: 10.1589/jpts.29.726
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Intra-rater reliabilities of lateral scapular slide test
| Position | Side | Measurement (mm) | ICC (95% CI) | |
|---|---|---|---|---|
| 1st | 2nd | |||
| Position 1 | Left | 8.81 ± 1.63 | 8.75 ± 1.68 | 0.730 (0.61–0.81)* |
| Right | 8.50 ± 1.45 | 8.77 ± 1.43 | 0.842 (0.77–0.89)* | |
| Position 2 | Left | 8.94 ± 1.80 | 8.95 ± 1.84 | 0.818 (0.74–0.87)* |
| Right | 8.86 ± 1.68 | 8.90 ± 1.55 | 0.830 (0.76–0.88)* | |
| Position 3 | Left | 9.17 ± 1.80 | 8.84 ± 2.27 | 0.722 (0.59–0.81)* |
| Right | 9.03 ± 1.78 | 9.02 ± 2.02 | 0.801 (0.71–0.86)* | |
Mean ± SD, *p<0.05, ICC: intraclass correlation coefficient, CI: confidence interval, Position 1: LSST with shoulder abduction at 0 degrees, Position 2: LSST with shoulder abduction at 45 degrees, Position 3: LSST with shoulder abduction at 90 degrees
Inter-rater reliabilities of lateral scapular slide test
| Position | Side | Measurement (mm) | ICC (95% CI) | |
|---|---|---|---|---|
| Examiner 1 | Examiner 2 | |||
| Position 1 | Left | 8.81 ± 1.63 | 8.71 ± 1.49 | 0.937 (0.91–0.96)* |
| Right | 8.50 ± 1.45 | 8.59 ± 1.53 | 0.929 (0.90–0.95)* | |
| Position 2 | Left | 8.94 ± 1.80 | 9.10 ± 1.99 | 0.925 (0.89–0.95)* |
| Right | 8.86 ± 1.68 | 8.86 ± 1.73 | 0.968 (0.95–0.98)* | |
| Position 3 | Left | 9.17 ± 1.80 | 8.87 ± 1.84 | 0.918 (0.88–0.94)* |
| Right | 9.03 ± 1.78 | 8.79 ± 1.97 | 0.920 (0.89–0.94)* | |
Mean ± SD, *p<0.05, ICC: intraclass correlation coefficient, CI: confidence interval, Position 1: LSST with shoulder abduction at 0 degrees, Position 2: LSST with shoulder abduction at 45 degrees, Position 3: LSST with shoulder abduction at 90 degrees