Literature DB >> 28533136

Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials.

Alanna Weisman1, Johnny-Wei Bai2, Marina Cardinez2, Caroline K Kramer3, Bruce A Perkins3.   

Abstract

BACKGROUND: Closed-loop artificial pancreas systems have been in development for several years, including assessment in numerous varied outpatient clinical trials. We aimed to summarise the efficacy and safety of artificial pancreas systems in outpatient settings and explore the clinical and technical factors that can affect their performance.
METHODS: We did a systematic review and meta-analysis of randomised controlled trials comparing artificial pancreas systems (insulin only or insulin plus glucagon) with conventional pump therapy (continuous subcutaneous insulin infusion [CSII] with blinded continuous glucose monitoring [CGM] or unblinded sensor-augmented pump [SAP] therapy) in adults and children with type 1 diabetes. We searched Medline, Embase, and the Cochrane Central Register of Controlled Trials for studies published from 1946, to Jan 1, 2017. We excluded studies not published in English, those involving pregnant women or participants who were in hospital, and those testing adjunct medications other than glucagon. The primary outcome was the mean difference in percentage of time blood glucose concentration remained in target range (3·9-10 mmol/L or 3·9-8 mmol/L, depending on the study), assessed by random-effects meta-analysis. This study is registered with PROSPERO, number 2015:CRD42015026854.
FINDINGS: We identified 984 reports; after exclusions, 27 comparisons from 24 studies (23 crossover and one parallel design) including a total of 585 participants (219 in adult studies, 265 in paediatric studies, and 101 in combined studies) were eligible for analysis. Five comparisons assessed dual-hormone (insulin and glucagon), two comparisons assessed both dual-hormone and single-hormone (insulin only), and 20 comparisons assessed single-hormone artificial pancreas systems. Time in target was 12·59% higher with artificial pancreas systems (95% CI 9·02-16·16; p<0·0001), from a weighted mean of 58·21% for conventional pump therapy (I2=84%). Dual-hormone artificial pancreas systems were associated with a greater improvement in time in target range compared with single-hormone systems (19·52% [95% CI 15·12-23·91] vs 11·06% [6·94 to 15·18]; p=0·006), although six of seven comparisons compared dual-hormone systems to CSII with blinded CGM, whereas 21 of 22 single-hormone comparisons had SAP as the comparator. Single-hormone studies had higher heterogeneity than dual-hormone studies (I2 79% vs 66%). Bias assessment characteristics were incompletely reported in 12 of 24 studies, no studies masked participants to the intervention assignment, and masking of outcome assessment was not done in 12 studies and was unclear in 12 studies.
INTERPRETATION: Artificial pancreas systems uniformly improved glucose control in outpatient settings, despite heterogeneous clinical and technical factors. FUNDING: None.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28533136     DOI: 10.1016/S2213-8587(17)30167-5

Source DB:  PubMed          Journal:  Lancet Diabetes Endocrinol        ISSN: 2213-8587            Impact factor:   32.069


  116 in total

1.  Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes.

Authors:  Sue A Brown; Boris P Kovatchev; Dan Raghinaru; John W Lum; Bruce A Buckingham; Yogish C Kudva; Lori M Laffel; Carol J Levy; Jordan E Pinsker; R Paul Wadwa; Eyal Dassau; Francis J Doyle; Stacey M Anderson; Mei Mei Church; Vikash Dadlani; Laya Ekhlaspour; Gregory P Forlenza; Elvira Isganaitis; David W Lam; Craig Kollman; Roy W Beck
Journal:  N Engl J Med       Date:  2019-10-16       Impact factor: 91.245

2.  The Clinical Case for the Integration of a Ketone Sensor as Part of a Closed Loop Insulin Pump System.

Authors:  Melissa H Lee; Barbora Paldus; Balasubramanium Krishnamurthy; Sybil A McAuley; Rajiv Shah; Alicia J Jenkins; David N O'Neal
Journal:  J Diabetes Sci Technol       Date:  2019-01-10

Review 3.  Role of Glucagon in Automated Insulin Delivery.

Authors:  Leah M Wilson; Peter G Jacobs; Jessica R Castle
Journal:  Endocrinol Metab Clin North Am       Date:  2019-12-10       Impact factor: 4.741

Review 4.  Automated Insulin Delivery in Adults.

Authors:  Charlotte K Boughton; Roman Hovorka
Journal:  Endocrinol Metab Clin North Am       Date:  2019-12-16       Impact factor: 4.741

5.  Fully Closed-Loop Multiple Model Probabilistic Predictive Controller Artificial Pancreas Performance in Adolescents and Adults in a Supervised Hotel Setting.

Authors:  Gregory P Forlenza; Faye M Cameron; Trang T Ly; David Lam; Daniel P Howsmon; Nihat Baysal; Georgia Kulina; Laurel Messer; Paula Clinton; Camilla Levister; Stephen D Patek; Carol J Levy; R Paul Wadwa; David M Maahs; B Wayne Bequette; Bruce A Buckingham
Journal:  Diabetes Technol Ther       Date:  2018-04-16       Impact factor: 6.118

6.  Use of Artificial Intelligence to Improve Diabetes Outcomes in Patients Using Multiple Daily Injections Therapy.

Authors:  Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2019-06       Impact factor: 6.118

7.  A Clinical Guide to Advanced Diabetes Devices and Closed-Loop Systems Using the CARES Paradigm.

Authors:  Laurel H Messer; Cari Berget; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2019-05-29       Impact factor: 6.118

8.  A qualitative study exploring the expectations of people living with type 1 diabetes regarding prospective use of a hybrid closed-loop system.

Authors:  A Quintal; V Messier; R Rabasa-Lhoret; E Racine
Journal:  Diabet Med       Date:  2020-05-13       Impact factor: 4.359

9.  Patient Perception and Satisfaction With Insulin Pump System: Pilot User Experience Survey.

Authors:  Maria Adela Grando; Mike Bayuk; George Karway; Krystal Corrette; Danielle Groat; Curtiss B Cook; Bithika Thompson
Journal:  J Diabetes Sci Technol       Date:  2019-05-05

10.  Evening and overnight closed-loop control versus 24/7 continuous closed-loop control for type 1 diabetes: a randomised crossover trial.

Authors:  Boris P Kovatchev; Laura Kollar; Stacey M Anderson; Charlotte Barnett; Marc D Breton; Kelly Carr; Rachel Gildersleeve; Mary C Oliveri; Christian A Wakeman; Sue A Brown
Journal:  Lancet Digit Health       Date:  2020-01-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.