Morcellation Efficiency in Holmium Laser Enucleation of the Prostate: Oscillating Morcellator Outperforms Reciprocating Morcellator With no Apparent Learning Curve.

Sean McAdams1, Rafael Nunez-Nateras2, Christopher J Martin2, Stephen Cha2, Mitchell R Humphreys2.   

Abstract

OBJECTIVE: To compare the morcellation efficiency of the Wolf Piranha oscillating morcellator with the Lumenis VersaCut reciprocating morcellator.
MATERIALS AND METHODS: After institutional review board approval, we conducted a retrospective analysis of patients undergoing holmium laser enucleation of the prostate (HoLEP) for symptomatic benign prostatic hyperplasia. The first 41 cases of HoLEP with morcellation performed with the oscillating morcellator were matched by weight of resected tissue to 41 control patients from our historic data set who underwent morcellation with the reciprocating system. The primary outcome of interest was morcellation efficiency. We also evaluated surgeon experience level to assess for a learning curve with the oscillating morcellator.
RESULTS: The 41 patients from each group were comparable in terms of age, prostate size, continuation of aspirin, and catheter status. The oscillating morcellation efficiency was nearly double that of the reciprocating morcellator (8.6 g/min [range: 3.0-18.3] vs 3.8 g/min [range: 0.9-10.1], P <.0001). Mean resected weights for cases with the oscillating and reciprocating instruments were 69 g (range: 17-224 g) and 69 g (range: 17-213 g), respectively (P = .9). The total operative time and complication rates did not significantly differ. For the oscillating system, morcellation efficiency for cases performed by staff alone was 9.8 g/min compared with 8.1 g/min when trainees were involved (P = .2), and there was no correlation between morcellation efficiency and number of cases performed (R = 0.01).
CONCLUSION: The oscillating morcellation system resulted in a morcellation efficiency double that of the reciprocating system for tissue retrieval after HoLEP. Achieving efficiency with the oscillating system was not associated with a significant learning curve and was not impacted by trainee involvement.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28532766     DOI: 10.1016/j.urology.2017.05.018

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  1 in total

1.  DrillCutTM vs VersaCutTM prostate tissue morcellation devices after holmium laser enucleation: A prospective, randomized controlled trial.

Authors:  Ahmed Ibrahim; Mostafa M Elhilali; Mohammed A Elkoushy; Sero Andonian; Serge Carrier
Journal:  Can Urol Assoc J       Date:  2018-12-03       Impact factor: 1.862

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.