Literature DB >> 28532050

Full in-vitro analyses of new-generation bulk fill dental composites cured by halogen light.

Tuçe Hazal Tekin1, Aysel Kantürk Figen2, Pınar Yılmaz Atalı3, Bilge Coşkuner Filiz4, Mehmet Burçin Pişkin1.   

Abstract

The objective of this study was to investigate the full in-vitro analyses of new-generation bulk-fill dental composites cured by halogen light (HLG). Two types' four composites were studied: Surefill SDR (SDR) and Xtra Base (XB) as bulk-fill flowable materials; QuixFill (QF) and XtraFill (XF) as packable bulk-fill materials. Samples were prepared for each analysis and test by applying the same procedure, but with different diameters and thicknesses appropriate to the analysis and test requirements. Thermal properties were determined by thermogravimetric analysis (TG/DTG) and differential scanning calorimetry (DSC) analysis; the Vickers microhardness (VHN) was measured after 1, 7, 15 and 30days of storage in water. The degree of conversion values for the materials (DC, %) were immediately measured using near-infrared spectroscopy (FT-IR). The surface morphology of the composites was investigated by scanning electron microscopes (SEM) and atomic-force microscopy (AFM) analyses. The sorption and solubility measurements were also performed after 1, 7, 15 and 30days of storage in water. In addition to his, the data were statistically analyzed using one-way analysis of variance, and both the Newman Keuls and Tukey multiple comparison tests. The statistical significance level was established at p<0.05. According to the ISO 4049 standards, all the tested materials showed acceptable water sorption and solubility, and a halogen light source was an option to polymerize bulk-fill, resin-based dental composites.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bulk fill resin composite; Dental; Flowable; Halogen light; In-vitro analyses; Packable

Mesh:

Substances:

Year:  2017        PMID: 28532050     DOI: 10.1016/j.msec.2017.03.251

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  3 in total

Review 1.  [Factors influencing clinical application of bulk-fill composite resin].

Authors:  Jing Xue
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-06-01

2.  The effect of pre-heating on monomer elution from bulk-fill resin composites.

Authors:  Mohammad-Esmaeel Ebrahimi-Chaharom; Leila Safyari; Hossein Safarvand; Elmira Jafari-Navimipour; Parnian Alizadeh-Oskoee; Amir-Ahmad Ajami; Mahdi Abed-Kahnamouei; Mahmoud Bahari
Journal:  J Clin Exp Dent       Date:  2020-09-01

3.  Effect of over the counter mouthwashes with and without alcohol on sorption and solubility of bulk fill resins.

Authors:  Vera Prado; Karen Santos; Raíssa Fontenele; Joseane Soares; Glauber Vale
Journal:  J Clin Exp Dent       Date:  2020-12-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.