Intra-observer reliability and agreement of manual and digital orthodontic model analysis.

Vasiliki Koretsi1, Linda Tingelhoff1, Peter Proff1, Christian Kirschneck1.   

Abstract

Background and aim: Digital orthodontic model analysis is gaining acceptance in orthodontics, but its reliability is dependent on the digitalisation hardware and software used. We thus investigated intra-observer reliability and agreement / conformity of a particular digital model analysis work-flow in relation to traditional manual plaster model analysis. Materials and methods: Forty-eight plaster casts of the upper/lower dentition were collected. Virtual models were obtained with orthoX®scan (Dentaurum) and analysed with ivoris®analyze3D (Computer konkret). Manual model analyses were done with a dial caliper (0.1 mm). Common parameters were measured on each plaster cast and its virtual counterpart five times each by an experienced observer. We assessed intra-observer reliability within method (ICC), agreement/conformity between methods (Bland-Altman analyses and Lin's concordance correlation), and changing bias (regression analyses).
Results: Intra-observer reliability was substantial within each method (ICC ≥ 0.7), except for five manual outcomes (12.8 per cent). Bias between methods was statistically significant, but less than 0.5 mm for 87.2 per cent of the outcomes. In general, larger tooth sizes were measured digitally. Total difference maxilla and mandible had wide limits of agreement (-3.25/6.15 and -2.31/4.57 mm), but bias between methods was mostly smaller than intra-observer variation within each method with substantial conformity of manual and digital measurements in general. No changing bias was detected. Conclusions: Although both work-flows were reliable, the investigated digital work-flow proved to be more reliable and yielded on average larger tooth sizes. Averaged differences between methods were within 0.5 mm for directly measured outcomes but wide ranges are expected for some computed space parameters due to cumulative error.
© The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

Mesh:

Year:  2018        PMID: 28531341     DOI: 10.1093/ejo/cjx040

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  Side effects of twistflex retainers-3D evaluation of tooth movement after retainer debonding.

Authors:  Isabel Knaup; Jenny Rosa Bartz; Ulrike Schulze-Späte; Rogério Bastos Craveiro; Christian Kirschneck; Michael Wolf
Journal:  J Orofac Orthop       Date:  2020-12-01       Impact factor: 1.938

2.  The effect of regular dental cast artifacts on the 3D superimposition of serial digital maxillary dental models.

Authors:  Eva Henninger; Georgios Vasilakos; Demetrios Halazonetis; Nikolaos Gkantidis
Journal:  Sci Rep       Date:  2019-07-19       Impact factor: 4.379

3.  Comparison between stone and digital cast measurements in mixed dentition : Validity, reliability, reproducibility, and objectivity.

Authors:  Lisa Schieffer; Lukas Latzko; Hanno Ulmer; Natalie Schenz-Spisic; Ulrike Lepperdinger; Magdalena Paulus; Adriano G Crismani
Journal:  J Orofac Orthop       Date:  2022-03-03       Impact factor: 2.341

4.  Evaluation of the accuracy of orthodontic models prototyped with entry-level LCD-based 3D printers: a study using surface-based superimposition and deviation analysis.

Authors:  Antonino Lo Giudice; Vincenzo Ronsivalle; Lorenzo Rustico; Kaled Aboulazm; Gaetano Isola; Giuseppe Palazzo
Journal:  Clin Oral Investig       Date:  2021-06-07       Impact factor: 3.573

5.  Reliability of Tooth Width Measurements Delivered by the Clin-Check Pro 6.0 Software on Digital Casts: A Cross-Sectional Study.

Authors:  Milagros Adobes Martin; Erica Lipani; Laura Bernes Martinez; Alfonso Alvarado Lorenzo; Riccardo Aiuto; Daniele Garcovich
Journal:  Int J Environ Res Public Health       Date:  2022-03-17       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.