Literature DB >> 285296

Blood flow and heat transfer in Walker 256 mammary carcinoma.

R K Jain, F H Grantham, P M Gullino.   

Abstract

True thermal conductivity of 13 Walker 256 mammary carcinomas in noninbred Sprague-Dawley rats averaged 3.2+/-0.9 mW/cm/degrees C under physiologic conditions. A comparison of the effective thermal conductivity in 4 tumors with and without blood flow revealed large differences ranging from 14 to 132%. When the blood supply to the tumor was doubled or reduced to one-half, the effective thermal conductivity varied proportionally to the square root of the perfusion rate. The values of thermal conductivity were obtained from a tumor preparation in which blood flow was monitored continuously during temperature changes. These changes were measured by thermistors and produced by thermal probes incorporated by the growing tumor, not surgically inserted within the tissue at the time of measurement. Inasmuch as tissue necrosis was not a dominant factor, the data are interpreted to reflect the degree of difference in local perfusion of the neoplastic tissue.

Entities:  

Mesh:

Year:  1979        PMID: 285296

Source DB:  PubMed          Journal:  J Natl Cancer Inst        ISSN: 0027-8874            Impact factor:   13.506


  6 in total

1.  A theoretical model for intraperitoneal delivery of cisplatin and the effect of hyperthermia on drug penetration distance.

Authors:  Ardith W El-Kareh; Timothy W Secomb
Journal:  Neoplasia       Date:  2004 Mar-Apr       Impact factor: 5.715

2.  Effect of temperature on the myoglobin-facilitated transport of oxygen in skeletal muscle.

Authors:  M K Dowd; R Murali; R C Seagrave
Journal:  Biophys J       Date:  1991-07       Impact factor: 4.033

3.  Correlation between size and external temperature in four rat tumours after treatment with cytostatic agents.

Authors:  P Nickers; L Oosters; F Brasseur; I Kunkler; H Maisin; C Deckers
Journal:  J Cancer Res Clin Oncol       Date:  1988       Impact factor: 4.553

4.  Physiological model for the pharmacokinetics of cis-dichlorodiammineplatinum (II) (DDP) in the tumored rat.

Authors:  F F Farris; F G King; R L Dedrick; C L Litterst
Journal:  J Pharmacokinet Biopharm       Date:  1985-02

Review 5.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

6.  Temperature simulations in hyperthermia treatment planning of the head and neck region: rigorous optimization of tissue properties.

Authors:  René F Verhaart; Zef Rijnen; Valerio Fortunati; Gerda M Verduijn; Theo van Walsum; Jifke F Veenland; Margarethus M Paulides
Journal:  Strahlenther Onkol       Date:  2014-11       Impact factor: 3.621

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.