Literature DB >> 28529343

Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection.

Jiri Gallo1, Jarmila Juranova2, Michal Svoboda1, Jana Zapletalova3.   

Abstract

BACKGROUND AND AIM: The aim of this study was to evaluate the characteristics of synovial fluid (SF) white cell count (SWCC) and neutrophil/lymphocyte percentage in the diagnosis of prosthetic joint infection (PJI) for particular threshold values. METHODS AND
RESULTS: This was a prospective study of 391 patients in whom SF specimens were collected before total joint replacement revisions. SF was aspirated before joint capsule incision. The PJI diagnosis was based only on non-SF data. Receiver operating characteristic plots were constructed for the SWCC and differential counts of leukocytes in aspirated fluid. Logistic binomic regression was used to distinguish infected and non-infected cases in the combined data. PJI was diagnosed in 78 patients, and aseptic revision in 313 patients. The areas (AUC) under the curve for the SWCC, the neutrophil and lymphocyte percentages were 0.974, 0.962, and 0.951, respectively. The optimal cut-off for PJI was 3,450 cells/μL, 74.6% neutrophils, and 14.6% lymphocytes. Positive likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 19.0, 10.4, and 9.5, respectively. Negative likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 0.06, 0.076, and 0.092, respectively.
CONCLUSIONS: Based on AUC, the present study identified cut-off values for the SWCC and differential leukocyte count for the diagnosis of PJI. The likelihood ratio for positive/negative SWCCs can significantly change the pre-test probability of PJI.

Entities:  

Keywords:  ROC curves; lymphocyte percentage; neutrophil percentage; prosthetic joint infection; synovial white cell count

Mesh:

Substances:

Year:  2017        PMID: 28529343     DOI: 10.5507/bp.2017.021

Source DB:  PubMed          Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub        ISSN: 1213-8118            Impact factor:   1.245


  3 in total

Review 1.  Diagnosis and management of implant debris-associated inflammation.

Authors:  Stuart B Goodman; Jiri Gallo; Emmanuel Gibon; Michiaki Takagi
Journal:  Expert Rev Med Devices       Date:  2019-12-17       Impact factor: 3.166

2.  Serum IL-6 in combination with synovial IL-6/CRP shows excellent diagnostic power to detect hip and knee prosthetic joint infection.

Authors:  Jiri Gallo; Michal Svoboda; Jana Zapletalova; Jitka Proskova; Jarmila Juranova
Journal:  PLoS One       Date:  2018-06-21       Impact factor: 3.240

3.  Soluble Pecam-1 as a Biomarker in Periprosthetic Joint Infection.

Authors:  Michael Fuchs; Andrej Trampuz; Stephanie Kirschbaum; Tobias Winkler; F Andrea Sass
Journal:  J Clin Med       Date:  2021-02-05       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.