Literature DB >> 28527280

[Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].

María Imaz1, Sonia Allassia, Mónica Aranibar, Alba Gunia, Susana Poggi, Ana Togneri, Lidia Wolff, Group Of Implementation Of Fluorescence.   

Abstract

INTRODUCTION: Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance.
OBJECTIVE: To evaluate the performance of LED-FM for tuberculosis diagnosis in patients with and without HIV infection using a newer, less expensive LED lamp.
MATERIALS AND METHODS: We compared the performance of LED-FM and Ziehl-Neelsen (ZN) microscopy on respiratory specimen smears from tuberculosis (TB) suspects and patients on treatment examined by different technicians blinded for HIV-status and for the result of the comparative test. We analyzed the effect of concentrating specimens prior to microscopy using different examination schemes and user-appraisal of the LED device.
RESULTS: Of the 6,968 diagnostic specimens collected, 869 (12.5%) had positive Mycobacterium tuberculosis cultures. LED-FM was 11.4% more sensitive than ZN (p;0.01). Among HIV-positive TB patients, sensitivity differences between LED-FM and ZN (20.6%) doubled the figure obtained in HIVnegative patients or in those with unknown HIV status (9.3%). After stratifying by direct and concentrated slides, the superiority of LED-FM remained. High specificity values were obtained both with LED-FM(99.9%) and ZN (99.9%).The second reading of a sample of slides showed a significantly higher positive detection yield using 200x magnification (49.4 %) than 400x magnification (33.8%) (p;0.05). The LEDdevice had a very good acceptance among the technicians.
CONCLUSION: LED-FM better performance compared with ZN in HIV-infected patients and user-appraisal support the rapid roll-out of LED-FM. Screening at 200x magnification was essential to achieve LEDFM increased sensitivity.

Entities:  

Keywords:  Tuberculosis; acid-fast bacilli; diagnosis; fluorescence; microscopy; sputum

Mesh:

Year:  2017        PMID: 28527280     DOI: 10.7705/biomedica.v37i2.3276

Source DB:  PubMed          Journal:  Biomedica        ISSN: 0120-4157            Impact factor:   0.935


  1 in total

1.  Bacterial profile and drug susceptibility among adult patients with community acquired lower respiratory tract infection at tertiary hospital, Southern Ethiopia.

Authors:  Alemitu Beyene Gebre; Tsegaye Alemayehu Begashaw; Moges Desta Ormago
Journal:  BMC Infect Dis       Date:  2021-05-13       Impact factor: 3.090

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.