BACKGROUND: The triple airway maneuver insertion technique allowed faster insertion of the LMA. This study compared three different insertion techniques of the laryngeal mask airway-Unique™.
METHODS: One hundred and eighty ASA I-II patients aged 18-65 years were included into the study. Patients were randomly allocated to the standard, rotational and triple airway maneuver (triple) group. In the standard group (n=60), the LMA (Laryngeal Mask Airway) was inserted with digital intraoral manipulation. In the triple group (n=60), the LMA was inserted with triple airway maneuver (mouth opening, head extension and jaw thrust). In the rotational group (n=60), LMA was inserted back-to-front, like a Guedel airway. Successful insertion at first attempt, time for successful insertion, fiber optic assessment, airway morbidity and hemodynamic responses were assessed.
RESULTS: Successful insertion at the first attempt was 88.3% for the standard, 78.3% for the rotational and 88.3% for the triple group. Overall success rate (defined as successful insertion at first and second attempt) was 93% for the standard, 90% for the rotational and 95% for the triple group. Time for successful insertion was significantly shorter in the triple group (mean [range] 8.63 [5-19]s) compared with the standard (11.78 [6-24]s) and rotational group (11.57 [5-31]s). Fiber optic assessment, airway morbidity and hemodynamic responses were similar in all groups.
CONCLUSIONS: Rotational and triple airway maneuver insertion techniques are acceptable alternatives. Triple airway maneuver technique shows higher overall success rates and allows shorter insertion time for LMA insertion and should therefore be kept in mind for emergent situations.
Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

Entities:  

Keywords:  Dispositivo supraglótico; Insertion technique; Laryngeal mask; Máscara laríngea; Supraglottic airway device; Técnica de inserção

Mesh:

Year:  2017        PMID: 28526466     DOI: 10.1016/j.bjan.2017.04.007

Source DB:  PubMed          Journal:  Rev Bras Anestesiol        ISSN: 0034-7094            Impact factor:   0.964


  2 in total

1.  Airway management using LMA-evaluation of three insertional techniques-a prospective randomised study.

Authors:  T Shyam; Venkatesh Selvaraj
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

2.  Novel Position for Laryngeal Mask Airway Insertion in Patients with Postburn Contracture over Neck: A Case Series.

Authors:  Prashant Shivaraj Sajjan; Vandana Sharashchandra Kulkarni
Journal:  Anesth Essays Res       Date:  2021-03-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.