Literature DB >> 28525849

Novel photoelectrochemical immunosensor for disease-related protein assisted by hemin/G-quadruplex-based DNAzyme on gold nanoparticles to enhance cathodic photocurrent on p-CuBi2O4 semiconductor.

Shuzhen Lv1, Kangyao Zhang1, Zhenzhen Lin1, Dianping Tang2.   

Abstract

A novel p-type semiconductor material (p-CuBi2O4) is designed for the construction of split-type photoelectrochemical (PEC) immunosensor for alpha-fetoprotein (AFP) with the hemin assistant to enhance the cathodic photocurrent. Initially, the photocathode of PEC immunosensor is fabricated by p-CuBi2O4 on a layer of gold nanoparticles (AuNPs, as a front contact of p-CuBi2O4) to enhance the efficiency of charge separation. In the presence of target AFP, a sandwich-type immunoreaction was carried out in capture antibody-coated microplate by using detection antibody and hemin-based G-quadruplex (labeled on the AuNP) as the signal probe. Upon exonuclease I (Exo I) introduction, the enzyme digested the hemin/G-quadruplex-based DNAzyme to release the hemin[Fe(III)], which captured the generated electrons of p-CuBi2O4-based photocathode to enhance photocurrent via the reduction of hemin[Fe(III)] to hemin[Fe(II)] in PEC detection system. Under the optimal conditions, the split-type photocathodic immunosensor showed a wide linear dynamic range from 50pgmL-1 to 20ngmL-1 at a limit of detection (LOD) of 14.7pgmL-1 toward target AFP. Moreover, the PEC immunosensor also displayed high specificity and good reproducibility. Favorably, method accuracy was evaluated to analyze human serum specimens, and gave matched-well results in comparison with commercially available enzyme-linked immunosorbent assay (ELISA) method.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Disease-related biomarker; Exonuclease I; Hemin/G-quadruplex-based DNAzyme; Split-type photoelectrochemical immunosensor; p-type CuBi(2)O(4) photocathodic material

Mesh:

Substances:

Year:  2017        PMID: 28525849     DOI: 10.1016/j.bios.2017.05.027

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  A carbon-rich nanofiber framework based on a conjugated arylacetylene polymer for photocathodic enzymatic bioanalysis.

Authors:  Junyan Tang; Xiaoya Liu; Chengwei Yang; Zhening Zhang; Rui Sun; Hongmei Li; Caolong Li; Fei Wang
Journal:  RSC Adv       Date:  2019-12-23       Impact factor: 3.361

Review 2.  Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.

Authors:  Xuan Liu; Hui Jiang
Journal:  Sensors (Basel)       Date:  2017-12-04       Impact factor: 3.576

3.  Aptasensor Based on Hierarchical Core-Shell Nanocomposites of Zirconium Hexacyanoferrate Nanoparticles and Mesoporous mFe3O4@mC: Electrochemical Quantitation of Epithelial Tumor Marker Mucin-1.

Authors:  Minghua Wang; Bin Hu; Hongfei Ji; Yingpan Song; Jiameng Liu; Donglai Peng; Linghao He; Zhihong Zhang
Journal:  ACS Omega       Date:  2017-10-17

Review 4.  Affinity-Based Detection of Biomolecules Using Photo-Electrochemical Readout.

Authors:  Amanda Victorious; Sudip Saha; Richa Pandey; Tohid F Didar; Leyla Soleymani
Journal:  Front Chem       Date:  2019-09-11       Impact factor: 5.221

5.  A highly sensitive bio-barcode immunoassay for multi-residue detection of organophosphate pesticides based on fluorescence anti-quenching.

Authors:  Lingyuan Xu; Xiuyuan Zhang; A M Abd El-Aty; Yuanshang Wang; Zhen Cao; Huiyan Jia; J-Pablo Salvador; Ahmet Hacimuftuoglu; Xueyan Cui; Yudan Zhang; Kun Wang; Yongxin She; Fen Jin; Lufei Zheng; Baima Pujia; Jing Wang; Maojun Jin; Bruce D Hammock
Journal:  J Pharm Anal       Date:  2022-05-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.