Literature DB >> 28524362

A novel chemiluminescence sensor for the determination of indomethacin based on sulfur and nitrogen co-doped carbon quantum dot-KMnO4 reaction.

Tooba Hallaj1, Mohammad Amjadi1, Jamshid L Manzoori1,2, Neda Azizi1.   

Abstract

We report on a simple and sensitive sulfur and nitrogen co-doped carbon quantum dot (S,N-CQD)-based chemiluminescence (CL) sensor for the determination of indomethacin. S,N-CQDs were prepared by a hydrothermal method and characterized by fluorescence spectra, Fourier transform infrared spectroscopy and transmission electron microscopy. To obtain the best CL system for determination of indomethacin, the reaction of S,N-CQDs with some common oxidants was studied. Among the tested systems, the S,N-CQD-KMnO4 reaction showed the highest sensitivity for the detection of indomethacin. Under optimum conditions, the calibration plot was linear over a concentration range of 0.1-1.5 mg L-1 , with a limit of detection (3σ) of 65 μg L-1 . The method was applied to the determination of indomethacin in environmental and biological samples with satisfactory results.
Copyright © 2017 John Wiley & Sons, Ltd.

Entities:  

Keywords:  carbon nanomaterial; chemiluminescence; indomethacin; sulfur and nitrogen co-doped carbon quantum dots

Mesh:

Substances:

Year:  2017        PMID: 28524362     DOI: 10.1002/bio.3306

Source DB:  PubMed          Journal:  Luminescence        ISSN: 1522-7235            Impact factor:   2.464


  4 in total

Review 1.  A Review on Graphene Quantum Dots for Electrochemical Detection of Emerging Pollutants.

Authors:  Solomon S Durodola; Abolanle S Adekunle; Lukman O Olasunkanmi; John A O Oyekunle; Odunayo T Ore; Samuel O Oluwafemi
Journal:  J Fluoresc       Date:  2022-08-30       Impact factor: 2.525

2.  Molecularly Imprinted Micelles for Fluorescent Sensing of Nonsteroidal Anti-Inflammatory Drugs (NSAIDs).

Authors:  Likun Duan; Yan Zhao
Journal:  React Funct Polym       Date:  2020-10-18       Impact factor: 3.975

3.  Synthesis and characterization of bipyridine cobalt(ii) complex modified graphite screen printed electrode: an electrochemical sensor for simultaneous detection of acetaminophen and naproxen.

Authors:  Tahere Kondori; Somayeh Tajik; Niloufar Akbarzadeh-T; Hadi Beitollahi; Cloudia Graiff; Ho Won Jang; Mohammadreza Shokouhimehr
Journal:  RSC Adv       Date:  2021-01-14       Impact factor: 3.361

4.  Dual Fluorescence in Glutathione-Derived Carbon Dots Revisited.

Authors:  Yadolah Ganjkhanlou; J J Erik Maris; Joris Koek; Romy Riemersma; Bert M Weckhuysen; Florian Meirer
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2022-01-26       Impact factor: 4.126

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.