Literature DB >> 28523414

Fully navigated 3 T proton magnetic resonance spectroscopy of liver metastases with inner-volume saturation.

Carolin Reischauer1,2,3, Andreas Hock4,5,6, Orpheus Kolokythas7, Christoph A Binkert7, Andreas Gutzeit8,9.   

Abstract

PURPOSE: To demonstrate that fully navigated magnetic resonance spectroscopy (MRS) with inner-volume saturation (IVS) at 3 T results in high-quality spectra that permit evaluating metabolic changes in hepatic metastases without the need for patient compliance.
METHODS: Nine patients with untreated, biopsy-proven large hepatic metastases (minimum diameter of 3 cm) were included. In each patient, localized proton MRS was performed in the metastatic lesion and in uninvolved liver parenchyma. To improve quality and consistency of proton MRS, navigator gating was thereby performed not only during acquisition of the spectroscopic data but also during localization imaging and throughout the preparation phases. IVS was utilized to reduce chemical shift displacement between different metabolites and to diminish flow artifacts. Metabolite quantities were normalized relative to the unsuppressed water peak and choline-containing compounds (CCC) to lipid ratios were determined. Wilcoxon signed-rank tests were used to assess differences in the amounts of lipids and CCC as well as the CCC-to-lipid ratios between liver metastases and normal-appearing liver parenchyma.
RESULTS: Fully navigated point-resolved spectroscopy with IVS resulted in high-quality spectra in all patients. Navigator gating during localization imaging and spectroscopic acquisition thereby ensured a precise localization of the spectroscopic voxel. Decreased quantities of lipid and CCC were observed in metastatic tissue compared with uninvolved liver parenchyma. However, the latter trend fell short of statistical significance. Moreover, elevated levels of the CCC-to-lipid ratios were detected in metastatic tissue relative to normal-appearing liver parenchyma.
CONCLUSIONS: The present study demonstrates that fully navigated MRS of the liver with IVS at 3 T allows for a precise localization of the spectroscopic voxel and results in high-quality spectra that permit evaluating liver metabolism without the need for patient compliance.

Entities:  

Keywords:  High field; In vivo; Liver metastases; Magnetic resonance spectroscopy; Navigator gating

Mesh:

Year:  2017        PMID: 28523414     DOI: 10.1007/s00261-017-1173-9

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  1 in total

1.  Two methods for assessment of choline status in a randomized crossover study with varying dietary choline intake in people: isotope dilution MS of plasma and in vivo single-voxel magnetic resonance spectroscopy of liver.

Authors:  David A Horita; Sunil Hwang; Julie M Stegall; Walter B Friday; David R Kirchner; Steven H Zeisel
Journal:  Am J Clin Nutr       Date:  2021-06-01       Impact factor: 7.045

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.