SU-E-T-586: Comparison between CT-and FLT-PET-Defined Target Volumes and Dosimetry for Radiotherapy Planning in Esophageal Carcinoma.

G Zhang1, Y Yin1, T Liu1, C Ma1.   

Abstract

PURPOSE: To study the advantage of fused 3-deoxy-3-18F-fluorothymidine (FLT) positron emission tomography (PET) and computed tomography (CT) images on radiotherapy planning for esophageal carcinoma patients .
METHODS: Ten patients with esophageal carcinoma were referred for radiotherapy. Each patient underwent CT and FLT PET scan for simulation plan in the same treatment position. FLT PET images were coregistered with CT images. GTVCT was initially performed on CT images, GTVPET-CT were automatically segmented on FLT PET/CT images using a fixed threshold values at 1.4. Two kinds of treatment plans were designed based on GTVCT and GTVPET-CT. The radiation dose was prescribed as 60 Gy in 30 fractions. The dose-volume parameters of target volume and normal tissues, CI and HI of based on the GTVPET- CT and GTVCT were compared.
RESULTS: The mean GTV delineated on CT and PET- CT were 39.28 cms and 34.48 cms , respectively . The values for mean lung dose, total-lung volume receiving =5, = 10, = 20 and = 30Gy;mean heart dose, heart volume receiving =30Gy and normal tissues of plan based on the GTVPET- CT were significant lower than plan based on the GTV-CT.
CONCLUSIONS: In our study, FLT PET use has an impact on target delineation for radiotherapy planning. GTVPET-CT is significantly smaller than GTVCT with a mean volume reduction of 16%. CT and FLT/PET image fusion appeared to have an advantage on dose reduction of organ at risk in radiotherapy planning of esophageal carcinoma.
© 2012 American Association of Physicists in Medicine.

Entities:  

Keywords:  Cancer; Computed tomography; Dosimetry; Heart; Medical image segmentation; Medical imaging; Positron emission tomography; Radiation therapy; Radiation treatment; Tissues

Year:  2012        PMID: 28517055     DOI: 10.1118/1.4735675

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  1 in total

1.  Comparison of gross target volumes based on four-dimensional CT, positron emission tomography-computed tomography, and magnetic resonance imaging in thoracic esophageal cancer.

Authors:  Huimin Li; Fengxiang Li; Jianbin Li; Youzhe Zhu; Yingjie Zhang; Yanluan Guo; Min Xu; Qian Shao; Xijun Liu
Journal:  Cancer Med       Date:  2020-06-08       Impact factor: 4.452

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.