Literature DB >> 28516796

Legionella spp. in dental unit waterlines.

E Sedlata Juraskova, H Sedlackova, J Janska, O Holy, I Lalova, I Matouskova.   

Abstract

OBJECTIVE: To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc.
MATERIAL AND METHODS: The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2).
RESULTS: From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella.
CONCLUSION: Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).

Entities:  

Keywords:  Legionella spp.; water of dental unit waterlines disinfection.

Mesh:

Substances:

Year:  2017        PMID: 28516796     DOI: 10.4149/BLL_2017_060

Source DB:  PubMed          Journal:  Bratisl Lek Listy        ISSN: 0006-9248            Impact factor:   1.278


  5 in total

Review 1.  Dental unit wastewater, a current environmental problem: a sistematic review.

Authors:  M E Cataldi; S Al Rakayan; C Arcuri; R Condò
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

2.  Occupational risk for Legionella infection among dental healthcare workers: meta-analysis in occupational epidemiology.

Authors:  Stefano Petti; Matteo Vitali
Journal:  BMJ Open       Date:  2017-07-13       Impact factor: 2.692

3.  Antimicrobial Effect of Visible Light-Photoinactivation of Legionella rubrilucens by Irradiation at 450, 470, and 620 nm.

Authors:  Julian Schmid; Katharina Hoenes; Petra Vatter; Martin Hessling
Journal:  Antibiotics (Basel)       Date:  2019-10-15

Review 4.  Legionella pneumophila-Virulence Factors and the Possibility of Infection in Dental Practice.

Authors:  Jasminka Talapko; Erwin Frauenheim; Martina Juzbašić; Matej Tomas; Suzana Matić; Melita Jukić; Marija Samardžić; Ivana Škrlec
Journal:  Microorganisms       Date:  2022-01-24

5.  Comparison between Two Types of Dental Unit Waterlines: How Evaluation of Microbiological Contamination Can Support Risk Containment.

Authors:  Jessica Lizzadro; Marta Mazzotta; Luna Girolamini; Ada Dormi; Tiziana Pellati; Sandra Cristino
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.