Fernanda de Paula Rossini1, Denise de Andrade2, Lissandra Chaves de Sousa Santos3, Adriano Menis Ferreira4, Caroline Tieppo5, Evandro Watanabe6.
Abstract
Objective: to evaluate the use of peripheral venous catheters based on microbiological analysis of devices (dressing and three-way stopcocks) and thus contribute to the prevention and infection control.Entities:
Mesh:
Year: 2017 PMID: 28513768 PMCID: PMC5465976 DOI: 10.1590/1518-8345.1528.2887
Source DB: PubMed Journal: Rev Lat Am Enfermagem ISSN: 0104-1169
Evaluation of bacterial growth on dressing, lumens and external surfaces of the three-way stopcocks used in peripheral venous catheters. Ribeirão Preto, SP, Brazil, 2015
| Devices | Bacterial Growth | Culture Medium ( | |
| n | % | ||
| Dressing | Present | 26 | 86.7 |
| Absent | 4 | 13.3 | |
| Three-way stopcocks lumen | Present | 12 | 40.0 |
| Absent | 18 | 60.0 | |
| Three-way stopcocks external surfaces | Present | 30 | 100 |
| Absent | 0 | 0 | |
Figure 1Evaluation of bacteria distribution in the samples of dressing, lumens and external surfaces of the three-way stopcocks used in peripheral venous catheters. Ribeirão Preto, SP, Brazil, 2015
Evaluation of numerical and percentage distribution of bacteria in dressing used in peripheral venous catheters according to antibiotics sensitivity profile. Ribeirão Preto, SP, Brazil, 2015
| Bacteria | Dressing | ||||
| Resistant (n=11) | Sensitive (n=14) | ||||
| n | % | n | % | ||
| Coagulase-negative
| 10* | 91.0 | 3 | 21.4 | |
|
| 0 | 0 | 3 | 21.4 | |
|
| 1 | 9.0 | 2 | 14.3 | |
|
| 0 | 0 | 2 | 14.3 | |
|
| 0 | 0 | 2 | 14.3 | |
|
| 0 | 0 | 1 | 7.10 | |
|
| 0 | 0 | 1 | 7.10 | |
* Methicillin-resistant coagulase-negative Staphylococcus.
† Carbapenem-resistant Klebsiella pneumoniae.
Evaluation of numerical and percentage distribution of bacteria in lumens of the three-way stopcocks used in peripheral venous catheters according to antibiotics sensitivity profile. Ribeirão Preto, SP, Brazil, 2015
| Bacteria | 3WSCs* lumen | ||||
| Resistant (n=5) | Sensitive (n=9) | ||||
| n | % | n | % | ||
| Coagulase-negative
| 5 | 100 | 2 | 22.2 | |
|
| 0 | 0 | 2 | 22.2 | |
|
| 0 | 0 | 2 | 22.2 | |
|
| 0 | 0 | 1 | 11.0 | |
|
| 0 | 0 | 1 | 11.0 | |
|
| 0 | 0 | 1 | 11.0 | |
* Methicillin-resistant coagulase-negative Staphylococcus.
Evaluation of numerical and percentage distribution of bacteria in external surfaces of the three-way stopcocks used in peripheral venous catheters according to antibiotics sensitivity profile. Ribeirão Preto, SP, Brazil, 2015
| Bacteria | 3WSCs* external surface | ||||
| Resistant (n=22) | Sensitive (n=15) | ||||
| n | % | n | % | ||
| Coagulase-negative
| 16 | 72.7 | 3 | 20.0 | |
|
| 2 | 9.0 | 3 | 20.0 | |
|
| 2 | 9.0 | 1 | 6.60 | |
|
| 1 | 4.5 | 1 | 6.60 | |
|
| 1 | 4.5 | 1 | 6.60 | |
|
| 0 | 0 | 2 | 13.3 | |
|
| 0 | 0 | 1 | 6.60 | |
|
| 0 | 0 | 1 | 6.60 | |
|
| 0 | 0 | 1 | 6.60 | |
|
| 0 | 0 | 1 | 6.60 | |
* Methicillin-resistant (coagulase-negative Staphylococcus and Staphylococcus aureus).
† Carbapenem-resistant (Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii).