Literature DB >> 28511078

Performance of electro-osmotic dewatering on different types of sewage sludge.

Simone Visigalli1, Andrea Turolla1, Paolo Gronchi2, Roberto Canziani3.   

Abstract

The feasibility of pressure-driven electro-dewatering (EDW) on sludge samples taken after different biological processes, stabilisation methods or mechanical dewatering techniques was assessed. First, the influence of potential values on EDW of anaerobically and aerobically stabilised, mechanically dewatered, sludge samples was investigated. Preliminary tests carried out by applying a constant potential (10, 15 and 20V) in a lab-scale device confirmed the possibility to reach a dry solid (DS) content of up to 42.9%, which corresponds to an increase of 15% of the dry content in dewatered sludge without the application of the electrical field. Dewatering increased with the applied potential but at the expense of a higher energy consumption. A potential equal to 15V was chosen as the best compromise for EDW performance, in terms of DS content and energy consumption. Then, the influence of the mechanical dewatering was studied on aerobically stabilised sludge samples with a lower initial DS content: the higher initial water content led to a lower final DS content but with a considerable reduction of energy consumption. Finally, the biological process, studied by comparing sludge samples from conventional activated sludge and membrane bioreactor processes, didn't evidence any influence on EDW. Experimental results shown that DS obtained after mechanical dewatering, volatile solids and conductivity are the main factors influencing EDW. Anaerobically digested sludge reached the highest DS content, thanks to lower organic fraction.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Electric field; Electro-dewatering; Electro-osmosis; Sewage sludge

Mesh:

Substances:

Year:  2017        PMID: 28511078     DOI: 10.1016/j.envres.2017.05.015

Source DB:  PubMed          Journal:  Environ Res        ISSN: 0013-9351            Impact factor:   6.498


  2 in total

1.  Enhancement of sludge electro-dewaterability during biological conditioning.

Authors:  Yingte Li; Yong Liu; Xiaoyan Yu; Qian Li; Rui Zhang; Shuting Zhang
Journal:  RSC Adv       Date:  2020-01-17       Impact factor: 4.036

2.  Coupling electro-dewatering and low-temperature air-drying for efficient dewatering of sludge.

Authors:  Hang Lv; Qiao Xiong; Daoguang Liu; Xu Wu
Journal:  Sci Rep       Date:  2021-09-27       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.