Literature DB >> 28508549

Prenatal prediction of postnatal large-for-dates neonates using a simplified MRI method: comparison with conventional 2D ultrasound estimates.

C Kadji1, M M Cannie2,3, R De Angelis2, M Camus1, M Klass1, S Fellas1, V Cecotti1, V Dütemeyer1, J C Jani1.   

Abstract

OBJECTIVE: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates.
METHODS: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al. and MRI-EFW on the formula described by Baker et al. For MRI-EFW, planimetric measurement of the fetal body volume (FBV) was performed using a semi-automated method and the time required for measurement was noted. Outcome measure was the performance of MRI-EFW vs US-EFW in the prediction of large-for-dates neonates, both ≤ 48 h and > 48 h before delivery. Receiver-operating characteristics (ROC) curves for each method were compared using the DeLong method.
RESULTS: Of the 270 women included in the first group, 48 (17.8%) newborns had birth weight ≥ 90th centile and 30 (11.1%) ≥ 95th centile. The second group included 83 women, and nine (10.8%) newborns had birth weight ≥ 95th centile. Median time needed for FBV planimetric measurements in all 353 fetuses was 3.5 (range, 1.5-5.5) min. The area under the ROC curve (AUC) for prediction of large-for-dates neonates by prenatal MRI performed within 48 h before delivery was significantly higher than that by US (for birth weight ≥ 90th centile, difference between AUCs = 0.085, standard error (SE) = 0.020, P < 0.001; for birth weight ≥ 95th centile, difference between AUCs = 0.036, SE = 0.014, P = 0.01). Similarly, MRI-EFW was better than US-EFW in predicting birth weight ≥ 95th centile when both examinations were performed > 48 h prior to delivery (difference between AUCs = 0.077, SE = 0.039, P = 0.045).
CONCLUSION: MRI planimetry using our purpose-designed semi-automated method is not time-consuming. The predictive performance of MRI-EFW performed immediately prior to or remote from delivery is significantly better than that of US-EFW for the prediction of large-for-dates neonates.
Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  2D ultrasound; estimation of weight; fetal weight; large-for-dates fetuses; macrosomia; magnetic resonance imaging; semi-automated software

Mesh:

Year:  2018        PMID: 28508549     DOI: 10.1002/uog.17523

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  Protocol for the prospective observational clinical study: estimation of fetal weight by MRI to PREdict neonatal MACROsomia (PREMACRO study) and small-for-gestational age neonates.

Authors:  Caroline Kadji; Mieke M Cannie; Andrew Carlin; Jacques C Jani
Journal:  BMJ Open       Date:  2019-03-27       Impact factor: 2.692

2.  Measuring intrauterine growth in healthy pregnancies using quantitative magnetic resonance imaging.

Authors:  Ariunzaya Amgalan; Kushal Kapse; Dhineshvikram Krishnamurthy; Nicole R Andersen; Rima Izem; Ahmet Baschat; Jessica Quistorff; Alexis C Gimovsky; Homa K Ahmadzia; Catherine Limperopoulos; Nickie N Andescavage
Journal:  J Perinatol       Date:  2022-02-23       Impact factor: 3.225

  2 in total