| Literature DB >> 2850829 |
M Dawson1, C M McGee, P M Brooks, J H Vine, T R Watson.
Abstract
A procedure for the quantification of leukotriene B4 (LTB4) in synovial fluid has been developed using gas chromatography/tandem mass spectrometry based on selected reaction monitoring of the elimination of t-butyldimethylsilanol from the ions of m/z 431 and 438 in the negative ion chemical ionization mass spectra of the di-t-butyldimethylsilyl/pentafluorobenzyl derivatives of leukotriene B4 and the internal standard (2H8)leukotriene B4. The detection limit (approximately 10 pg ml-1) is sufficiently low to permit determination of LTB4 concentration in the synovial fluid of patients with various arthropathies. Single-stage mass spectrometry was found not to be selective enough to permit quantification of LTB4 in synovial fluid.Entities:
Mesh:
Substances:
Year: 1988 PMID: 2850829 DOI: 10.1002/bms.1200170309
Source DB: PubMed Journal: Biomed Environ Mass Spectrom ISSN: 0887-6134