Edwards valve-in-valve implantation in tricuspid position.

Maria Álvarez-Fuente1, Nikolaus A Haas2, Maria Jesus Del Cerro1.   

Abstract

We present two cases of percutaneous Sapien XT valve-in-valve implantation in the tricuspid position: a 20-year-old man with severe congenital pulmonary stenosis and percutaneous valvuloplasty, who required surgical implantation of two protheses, pulmonary and tricuspid, and a 12-year-old boy with CHD and a degenerated tricuspid prosthesis. We implanted three Sapien XT valve-in-valves, two in the tricuspid position and one in the pulmonic position. Sapien XT valve-in-valve implantation in the tricuspid position is feasible and can decrease the number of surgeries in CHD patients.

Entities:  

Keywords:  CHD; percutaneous valve implantation; pulmonary valve disease; tricuspid valve disease

Mesh:

Year:  2017        PMID: 28506330     DOI: 10.1017/S1047951117000786

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  1 in total

1.  Transcatheter valve-in-valve-in-valve replacement in tricuspid position in a patient with pre-existing permanent dual-chamber pacemaker.

Authors:  Philipp Lake; Elmar W Kuhn; Victor Mauri; Sascha Macherey; Julia Kaliba; Stephan Baldus; Christian Frerker; Tobias Schmidt
Journal:  Clin Res Cardiol       Date:  2021-04-28       Impact factor: 5.460