Literature DB >> 28502856

DNA chip based sensor for amperometric detection of infectious pathogens.

Swati Singh1, Ankur Kaushal2, Shashi Khare3, Ashok Kumar4.   

Abstract

Several infectious pathogens are found in human whose detection is essential for rapid cure of diseases. The most commonly found pathogen in human is Streptococcus pyogenes which leads to a wide range of infections from mild pharyngitis to rheumatic heart disease. An ultrasensitive DNA chip based sensor was developed for quick identification of pathogen S. pyogenes from patient throat swab samples. The amperometric response was measured after hybridization of specific probe with single stranded genomic DNA (ssG-DNA) from the patient samples. The DNA chip was characterized by FTIR, SEM and validated with suspected patient real samples. The sensitivity of the DNA chip based sensor was found 951.34(μA/cm2)/ng DNA and lower limit of detection (LOD) was 130fg/6μL samples. The DNA chip based sensor is highly specific and takes only 30min for identification of specific pathogen.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DNA chip; PAMAM dendrimer; Pathogens; Rheumatic heart disease; Streptococcus pyogenes

Mesh:

Year:  2017        PMID: 28502856     DOI: 10.1016/j.ijbiomac.2017.05.041

Source DB:  PubMed          Journal:  Int J Biol Macromol        ISSN: 0141-8130            Impact factor:   6.953


  4 in total

Review 1.  Recent advances in rapid pathogen detection method based on biosensors.

Authors:  Ying Chen; Zhenzhen Wang; Yingxun Liu; Xin Wang; Ying Li; Ping Ma; Bing Gu; Hongchun Li
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-03-22       Impact factor: 3.267

2.  Leptospira interrogans Outer Membrane Protein-Based Nanohybrid Sensor for the Diagnosis of Leptospirosis.

Authors:  Vivek Verma; Deepak Kala; Shagun Gupta; Harsh Kumar; Ankur Kaushal; Kamil Kuča; Natália Cruz-Martins; Dinesh Kumar
Journal:  Sensors (Basel)       Date:  2021-04-06       Impact factor: 3.576

Review 3.  Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis.

Authors:  Alisa N Kozitsina; Tatiana S Svalova; Natalia N Malysheva; Andrei V Okhokhonin; Marina B Vidrevich; Khiena Z Brainina
Journal:  Biosensors (Basel)       Date:  2018-04-01

4.  Antibody Modified Gold Electrode as an Impedimetric Biosensor for the Detection of Streptococcus pyogenes.

Authors:  Natalia Malinowska; Wioleta Białobrzeska; Tomasz Łęga; Katarzyna Pałka; Karolina Dziąbowska; Sabina Żołędowska; Elżbieta Czaczyk; Katarzyna Pala; Dawid Nidzworski
Journal:  Sensors (Basel)       Date:  2020-09-17       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.