Literature DB >> 28502060

Comparison of Univent tube and EZ blocker in one lung ventilation; airway pressures and gas exchange.

Tülay Hoşten1, Can Aksu2, Alparslan Kuş2, Sevim Cesur2, Neşe Türkyılmaz2, Mine Solak2.   

Abstract

Univent tube (UT) and EZ-blocker were used for one-lung ventilation (OLV). UT is a single lumen tube with a small separate lumen containing a bronchial blocker. EZ-blocker differs with its unique y-shaped double-cuffed distal end. We aimed to compare these two airway devices effects on airway pressures, oxygenation, ventilation and haemodynamics during OLV. Patients undergoing elective thoracotomy for the first time were included in this prospective randomized study. Patients were divided into two groups as UT and EZ. Bronchial blockers (BB) placement time was recorded. In lateral decubitus position, airway pressures, static compliance, tidal volume (TV), respiratory rate (RR) and haemodynamic findings were recorded before inflating the BB cuff (Pre-OLV) and during OLV every 15 min. Arterial blood gas (ABG) samples were obtained before and during OLV. 70 patients were enrolled in the study. The demographic characteristics and data related to anesthesia and surgery were similar in both groups. It took longer to place EZ than UT (p = 0.02). Ppeak values were similar in both groups. Pplateau was significantly lower at the beginning of OLV (OLV15th min) and higher at the end of OLV (pre-DLV) in EZ group compared to UT (p = 0.01, p = 0.03). Cstatic were significantly higher at the beginning of OLV (OLV15th min) in EZ group compared to UT (p = 0.01). During the following measurements, Cstatic values were similar for both groups. Ventilation were achieved with similar TV and RR. ABG findings and haemodynamic variables were similar. EZ and Univent tube affected the airway pressures, oxygenation, ventilation and haemodynamic variables similarly during OLV in patients with normal respiratory function. These devices can be alternatives to each other based on clinical conditions.

Entities:  

Keywords:  Airway pressures; Bronchial blockers; EZ blocker; One lung ventilation; Thoracic surgery; Univent tube

Mesh:

Substances:

Year:  2017        PMID: 28502060     DOI: 10.1007/s10877-017-0028-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  30 in total

1.  Extraluminal EZ-blocker Placement for One-lung Ventilation in Pediatric Thoracic Surgery.

Authors:  Federico Piccioni; Irene Vecchi; Elena Spinelli; Paola Previtali; Martin Langer
Journal:  J Cardiothorac Vasc Anesth       Date:  2015-05-27       Impact factor: 2.628

2.  Searching for the ideal endobronchial blocker.

Authors:  Jo Mourisse; Jos Lerou
Journal:  Anesthesiology       Date:  2013-10       Impact factor: 7.892

3.  The univent tube can facilitate difficult intubation in a patient undergoing thoracoscopy.

Authors:  A Baraka
Journal:  J Cardiothorac Vasc Anesth       Date:  1996-08       Impact factor: 2.628

4.  Flow resistances of disposable double-lumen, single-lumen, and Univent tubes.

Authors:  P D Slinger; L Lesiuk
Journal:  J Cardiothorac Vasc Anesth       Date:  1998-04       Impact factor: 2.628

5.  One-lung ventilation in a patient with a fresh tracheostomy using the tracheostomy tube and a Univent endobronchial blocker.

Authors:  M S Dhamee
Journal:  J Cardiothorac Vasc Anesth       Date:  1997-02       Impact factor: 2.628

Review 6.  Pro: one-lung ventilation is best accomplished with the Univent endotracheal tube.

Authors:  J M Gayes
Journal:  J Cardiothorac Vasc Anesth       Date:  1993-02       Impact factor: 2.628

7.  New device for one-lung anesthesia: endotracheal tube with movable blocker.

Authors:  H Inoue; A Shohtsu; J Ogawa; S Kawada; S Koide
Journal:  J Thorac Cardiovasc Surg       Date:  1982-06       Impact factor: 5.209

Review 8.  Relationship between ventilatory settings and barotrauma in the acute respiratory distress syndrome.

Authors:  Mohamed Boussarsar; Guillaume Thierry; Samir Jaber; Françoise Roudot-Thoraval; François Lemaire; Laurent Brochard
Journal:  Intensive Care Med       Date:  2002-01-15       Impact factor: 17.440

9.  Lung tissue and airway impedances during pulmonary edema in normal range of breathing.

Authors:  G M Barnas; J Sprung; R Kahn; P A Delaney; M Agarwal
Journal:  J Appl Physiol (1985)       Date:  1995-05

10.  Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema.

Authors:  G M Barnas; D Stamenović; K R Lutchen
Journal:  J Appl Physiol (1985)       Date:  1992-09
View more
  2 in total

1.  Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery-a randomised controlled clinical trial.

Authors:  Joachim Risse; Karsten Szeder; Ann-Kristin Schubert; Thomas Wiesmann; Hanns-Christian Dinges; Carsten Feldmann; Hinnerk Wulf; Karl Matteo Meggiolaro
Journal:  BMC Anesthesiol       Date:  2022-04-02       Impact factor: 2.217

2.  Extraluminal Placement of a Bronchial Blocker Compared with Carbon Dioxide Artificial Pneumothorax in Infants Undergoing Video-Assisted Thoracoscopic Surgery.

Authors:  Jing Wang; Wen-Peng Xie; Yu-Qing Lei; Ling-Shan Yu; Zeng-Chun Wang; Hua Cao; Qiang Chen
Journal:  Ann Thorac Cardiovasc Surg       Date:  2021-07-23       Impact factor: 1.520

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.