Literature DB >> 2850187

Use of profile analysis for the measurement of organ dimensions.

M K O'Connor1, W M Oswald, M L Brown, P S Kamath, S F Phillips.   

Abstract

We have developed a method for measurement of organ dimension based on the use of the full width half maximum (FWHM) of profiles taken through an organ. In vitro studies were performed using a large rectangular lucite box filled with water. Five circular lucite phantoms with internal diameters of 1.4-10.2 cm and 1 elliptical phantom with dimensions 9.6 x 4.0 cm were filled with 99mTc-pertechnetate at various concentrations. Phantoms were imaged on a gamma camera at a depth of 5-25 cm in water and the FWHM calculated from horizontal profiles taken across the cylinders. The FWHM showed no variation with 99mTc concentration in the same cylinder. Phantom profiles were deconvolved with a system line spread function measured under similar conditions of scatter and depth. The correction factor to convert the deconvolved profile FWHM to true diameter was independent of cylinder depth and diameter over a range of FWHM 3-10 cm and depth 5-25 cm. The mean value for the correction factor was 1.23 +/- 0.04 for circular phantoms and 1.14 +/- 0.02 for the elliptical phantom. This technique should allow an objective and reproducible estimate of organ dimensions from planar images that is relatively independent of the depth and size of an organ.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2850187     DOI: 10.1007/bf00286777

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Estimation of thyroid weight by scintigraphy.

Authors:  G Mandart; F Erbsmann
Journal:  Int J Nucl Med Biol       Date:  1975-10

2.  Activity per unit volume: a pitfall in predicting size.

Authors:  F S Mishkin; I Reese; P Vasinrapee; P Cunningham
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

3.  Difficulty of estimating biliary tract distention by radionuclide imaging.

Authors:  L Rosenthall; B Damtew; R Kloiber; R Warshawski
Journal:  Diagn Imaging       Date:  1981

4.  A computer-based scintigraphic method for sizing acute inferior myocardial infarcts.

Authors:  M H Lewis; L M Buja; R W Parkey; D J Mishelevich; F J Bonte; S I Saffer; J R Richmond; J T Willerson
Journal:  Radiology       Date:  1980-08       Impact factor: 11.105

5.  Accuracy or inaccuracy of spleen mass measurements from radionuclide images.

Authors:  H J Hazenberg; C J Muller
Journal:  Diagn Imaging Clin Med       Date:  1984

6.  Quantitative gallium-67 scanning for predictive value in primary lung carcinoma.

Authors:  I Higashi; H Wakao; K Nakamura; A Shimura; T Yokoyama; S Suzuki; K Watanabe; G D Kruglik
Journal:  J Nucl Med       Date:  1980-07       Impact factor: 10.057

7.  Prediction of spleen size by routine radioisotope scintigraphy.

Authors:  S Ingeberg; M Støckel; P J Sørensen
Journal:  Acta Haematol       Date:  1983       Impact factor: 2.195

  7 in total
  1 in total

1.  Colonic capacitance and transit in man: modulation by luminal contents and drugs.

Authors:  P S Kamath; S F Phillips; M K O'Connor; M L Brown; A R Zinsmeister
Journal:  Gut       Date:  1990-04       Impact factor: 23.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.