Literature DB >> 28501559

Fast, accurate and easy-to-teach QT interval assessment: The triplicate concatenation method.

Valentin Saqué1, Martino Vaglio2, Christian Funck-Brentano1, Maya Kilani1, Olivier Bourron3, Agnès Hartemann3, Fabio Badilini2, Joe-Elie Salem4.   

Abstract

BACKGROUND: The gold standard method for assessing the QTcF (QT corrected for heart rate by Fridericia's cube root formula) interval is the "QTcF semiautomated triplicate averaging method" (TAM), which consists of measuring three QTcF values semiautomatically, for each 10-second sequence of a triplicate electrocardiogram set, and averaging them to get a global and unique QTcF value. Thus, TAM is time consuming. We have developed a new method, namely the "QTcF semiautomated triplicate concatenation method" (TCM), which consists of concatenating the three 10-second sequences of the triplicate electrocardiogram set as if they were a single 30-second electrocardiogram, and measuring QTcF only once for the triplicate electrocardiogram set. AIM: To compare the TCM method with the TAM method.
METHODS: Fifty triplicate electrocardiograms were read twice by an expert and a student using both methods (TAM and TCM). We plotted Bland-Altman plots to assess agreement between the two methods, and to compare the student and expert results. The time needed to read a set of 20 consecutive triplicate electrocardiograms was measured.
RESULTS: Limits of agreement between TAM and TCM ranged from -8.25 to 6.75ms with the expert reader. TCM was twice as fast as TAM (17.38 versus 34.28min for 20 consecutive triplicate electrocardiograms). Bland-Altman plots comparing student and expert results showed limits of agreement ranging from -4.34 to 11.75ms for TAM, and -1.2 to 8.0ms for TCM.
CONCLUSIONS: TAM and TCM show good agreement for QT measurement. TCM is less time consuming than TAM. After a learning session, an inexperienced reader can measure the QT interval accurately with both methods.
Copyright © 2017 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Education; Mesure de l’intervalle QT; Mesure semi-automatique; Method validation; Pédagogie; QT interval measurement; Semiautomated measurement; Validation de méthode

Year:  2017        PMID: 28501559     DOI: 10.1016/j.acvd.2016.12.011

Source DB:  PubMed          Journal:  Arch Cardiovasc Dis        ISSN: 1875-2128            Impact factor:   2.340


  3 in total

1.  Association of Oral Contraceptives With Drug-Induced QT Interval Prolongation in Healthy Nonmenopausal Women.

Authors:  Joe-Elie Salem; Pauline Dureau; Anne Bachelot; Marine Germain; Pascal Voiriot; Bruno Lebourgeois; David-Alexandre Trégouët; Jean-Sébastien Hulot; Christian Funck-Brentano
Journal:  JAMA Cardiol       Date:  2018-09-01       Impact factor: 14.676

2.  Association of N-Acetyl Asparagine with QTc in Diabetes: A Metabolomics Study.

Authors:  Giacomo Gravina; Melissa Y Y Moey; Edi Prifti; Farid Ichou; Olivier Bourron; Elise Balse; Fabio Badillini; Christian Funck-Brentano; Joe-Elie Salem
Journal:  Biomedicines       Date:  2022-08-12

3.  A Randomized, Double-Blind, Placebo- and Positive-Controlled, 4-Period Crossover Study of the Effects of Solriamfetol on QTcF Intervals in Healthy Participants.

Authors:  Katie Zomorodi; Dan Chen; Lawrence Lee; Dennis Swearingen; Lawrence P Carter
Journal:  Clin Pharmacol Drug Dev       Date:  2020-09-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.