Reliability of home blood pressure monitoring devices in pregnancy.

Chris Tremonti1, Jennifer Beddoe2, Mark A Brown3.   

Abstract

Home blood pressure monitors are freely available and used for women during pregnancy. The exact role of home blood pressure monitoring in pregnancy remains uncertain, and few such monitors have been validated for use in pregnancy. As it has been our Unit's policy to test these devices against sphygmomanometry (as the gold standard) before clinical use for some years now, we undertook this study to ascertain the degree of accuracy or inaccuracy of these devices in usual clinical practice. We analysed 9 consecutive blood pressures (BP) alternately using an automated home BP device and sphygmomanometry in 127 pregnant women with hypertension using two different methods: a) a modified version of the British Hypertension Society's guidelines for analysing automated devices, and b) examining the difference between the mean of blood pressure readings by the device and sphygmomanometry for each patient. 87 devices (69%) had systolic BP within 5mmHg or less and 98 (77%) were within 5mmHg for diastolic BP. The frequency of systolic BPs within 5mmHg was similar for non-validated vs. validated devices (75vs. 60%; p=0.23). Similarly, diastolic BP within 5mmHg was similar for non-validated vs. validated devices (86vs. 68%, p=0.06). Our findings showed that a wide variety of devices are used and few if any have been formally validated for use in pregnancy. As a group the devices provide accurate BP in the majority of women, but up to a quarter will have a BP difference of at least 5mmHg, and this is not related to the absolute BP. Furthermore using a home BP device validated for general use in non-pregnant subjects appeared as reliable as using other non-validated devices. On the basis of these data we recommended clinicians always perform their own analysis of a patient's home BP machine accuracy prior to home use using a simple protocol as described here, even if the machine has been validated for general use.
Copyright © 2017 International Society for the Study of Hypertension in Pregnancy. All rights reserved.

Entities:  

Keywords:  Automated BP; Blood pressure; Gestational hypertension; Home blood pressure monitors; Pregnancy

Mesh:

Year:  2017        PMID: 28501284     DOI: 10.1016/j.preghy.2017.01.002

Source DB:  PubMed          Journal:  Pregnancy Hypertens        ISSN: 2210-7789            Impact factor:   2.899


  3 in total

Review 1.  Accuracy of Blood Pressure Measurement Devices in Pregnancy: A Systematic Review of Validation Studies.

Authors:  Natalie A Bello; Jonathan J Woolley; Kirsten Lawrence Cleary; Louise Falzon; Bruce S Alpert; Suzanne Oparil; Gary Cutter; Ronald Wapner; Paul Muntner; Alan T Tita; Daichi Shimbo
Journal:  Hypertension       Date:  2017-12-11       Impact factor: 10.190

2.  Baseline check of blood pressure readings of an automated device in severe pre-eclampsia and healthy normotensive pregnancy.

Authors:  Nnabuike C Ngene; Jagidesa Moodley
Journal:  Pregnancy Hypertens       Date:  2018-03-01       Impact factor: 2.899

3.  Home blood pressure monitoring in the diagnosis and treatment of hypertension in pregnancy: a systematic review and meta-analysis.

Authors:  Karen Tran; Raj Padwal; Nadia Khan; Mary-Doug Wright; Wee Shian Chan
Journal:  CMAJ Open       Date:  2021-06-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.