Literature DB >> 28501212

A selective and sensitive fluorescent probe for the determination of HSA and trypsin.

Shanshan Huang1, Fangfang Li2, Caiyun Liao1, Baozhan Zheng2, Juan Du3, Dan Xiao4.   

Abstract

A simple fluorescent probe HBI-GR based on the combination of the fluorophore (p-HBI) in green fluorescent protein (GFP) and Guanine riboside (GR) for HSA was successfully synthesized. HBI-GR showed an obvious fluorescence enhancement toward HSA without interference from other proteins, amino acids, anions and commonly existing metal ions. HBI-GR exhibited high sensitivity towards HSA with a good linear relationship between the fluorescence intensity of HBI-GR and HSA concentration from 0 to 0.06mgmL-1. The limit of detection, based on a signal-to-noise ratio of 3, was 15.09ngmL-1, which was much lower than that of most other reported probes. HBI-GR was almost non-fluorescent because of the bond twisting in the exited state of chromophore HBI. After binding to the hydrophobic pocket of HSA, it showed an obvious fluorescence enhancement due to the rigidifying of the flexible chromophore HBI by the hydrophobic environment. The resulting HBI-GR/HSA system also showed a satisfactory sensing ability toward trypsin through decreased fluorescence intensity with the detection limit of 0.0282ngmL-1. The fluorescence decreasing process was occurred as the lysine and arginine amino acids residues of HSA were cleaved by trypsin, which led to further exposure of HBI-GR to the PBS buffer phase and a concomitant decrease of the HBI-GR fluorescence intensity. Moreover, the probe HBI-GR was successfully used to detect HSA in healthy human urine and human blood serum samples. The practical application of the HBI-GR/HSA system for trypsin detection in healthy human urine also achieved satisfactory result.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluorescence; GFP; HBI; HSA; Trypsin

Mesh:

Substances:

Year:  2017        PMID: 28501212     DOI: 10.1016/j.talanta.2017.01.034

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  A Novel Detection Method of Human Serum Albumin Based on the Poly(Thymine)-Templated Copper Nanoparticles.

Authors:  Mingjian Chen; Xinying Xiang; Kefeng Wu; Hailun He; Hanchun Chen; Changbei Ma
Journal:  Sensors (Basel)       Date:  2017-11-21       Impact factor: 3.576

2.  Label-free Fluorescence Turn on Trypsin Assay Based on Gemini Surfactant/heparin/Nile Red Supramolecular Assembly.

Authors:  Nan Yuan; Lan Jia; Jingxin Zhu
Journal:  J Fluoresc       Date:  2021-07-28       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.