Literature DB >> 28501206

Simultaneous determination and speciation analysis of arsenic and chromium in iron supplements used for iron-deficiency anemia treatment by HPLC-ICP-MS.

Uenderson Araujo-Barbosa1, Elena Peña-Vazquez2, Maria Carmen Barciela-Alonso2, Sergio Luis Costa Ferreira3, Ana Maria Pinto Dos Santos3, Pilar Bermejo-Barrera4.   

Abstract

This work proposes the use of high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for simultaneous speciation of arsenic and chromium in iron supplements used for the treatment of anemia. The sample preparation procedure recommended for the total determination of arsenic and chromium was established using acid digestion in a microwave assisted oven. For speciation analysis, however, the microwave-assisted extraction procedure involved the use of water as extraction solvent at 90°C for 30min. The chromatographic separation was performed using a mobile phase containing 1.0mM tetrabutylammonium hydroxide (TBAH), 0.7mM ethylenediaminetetraacetic acid (EDTA) and 5% methanol at pH 7.2. Helium was used in the collision cell for elimination of the interferences. Under optimized conditions, the separation and detection of the As(III), As(V), Cr(III) and Cr(VI) species can be performed in 5min, permitting their quantification with the external calibration technique with standards prepared in the mobile phase. The limits of quantification obtained were 0.008, 0.010, 0.5 and 0.14µgg-1, for As(III), As(V), Cr(III) and Cr(VI), respectively. The accuracy of the method was evaluated and confirmed by addition/recovery tests. The recoveries obtained varied from 81% to 110%. The proposed method was applied to the speciation analysis of arsenic and chromium in commercially available iron supplements acquired in several cities in Brazil and Spain. The content of the species ranged from 0.01 to 1.3µgg-1 for arsenic, and from 0.4 to 61.2µgg-1 for chromium.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anemia; Arsenic; Chromium; HPLC–ICP-MS; Iron supplement; Speciation

Mesh:

Substances:

Year:  2017        PMID: 28501206     DOI: 10.1016/j.talanta.2017.04.034

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A paper-based optical probe for chromium by using gold nanoparticles modified with 2,2'-thiodiacetic acid and smartphone camera readout.

Authors:  Shadab Faham; Gholamreza Khayatian; Hamed Golmohammadi; Raouf Ghavami
Journal:  Mikrochim Acta       Date:  2018-07-13       Impact factor: 5.833

2.  Application of Liquid Chromatography Coupled to Mass Spectrometry in Quality Assessment of Dietary Supplements-A Case Study of Tryptophan Supplements: Release Assay, Targeted and Untargeted Studies.

Authors:  Krzysztof Adam Stępień; Joanna Giebułtowicz
Journal:  Pharmaceuticals (Basel)       Date:  2022-04-04

3.  Cationic Metal-Organic Framework-Based Mixed-Matrix Membranes for Fast Sensing and Removal of Cr2O7 2- Within Water.

Authors:  Shuyun Zhang; Heqi Zheng; Yu Yang; Guodong Qian; Yuanjing Cui
Journal:  Front Chem       Date:  2022-02-28       Impact factor: 5.221

Review 4.  Potential Point-of-Care Microfluidic Devices to Diagnose Iron Deficiency Anemia.

Authors:  Boon Kar Yap; Siti Nur'Arifah M Soair; Noor Azrina Talik; Wai Feng Lim; Lai Mei I
Journal:  Sensors (Basel)       Date:  2018-08-10       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.