Literature DB >> 28501144

Sequential injection differential pulse voltammetric method based on screen printed carbon electrode modified with carbon nanotube/Nafion for sensitive determination of paraquat.

Prakit Chuntib1, Suwaphid Themsirimongkon1, Surin Saipanya1, Jaroon Jakmunee2.   

Abstract

The screen-printed carbon electrode (SPCE) modified with various nanoparticles has been studied for using as a working electrode in voltammetric technique. The electrochemical behavior of paraquat on different electrodes was studied by cyclic voltammetry (CV), and then differential pulse voltammetry (DPV) has been employed for trace analysis of paraquat based on redox reaction which the peak current was directly proportional to the concentration of paraquat in the solution. The SPCE modified with carbon nanotube dispersed in Nafion and ethanol (SPCE-CNT/Nafion) gave the best result. Sequential injection-differential pulse voltammetric (SI-DPV) method has been developed for more automated analysis and to reduce chemical consumption. The parameters affecting the SI-DPV system such as step potential, modulation amplitude, flow rate, and concentration of sodium chloride as an electrolyte were studied to improve the sensitivity. Under the optimum condition of the system, i.e., Nafion concentration of 1% (w/v), volume of CNT suspension of 2µL, flow rate of 100µLs-1, step potential of 5mV, modulation amplitude of 100mV and concentration of sodium chloride of 1M, a linear calibration graph in the range of 0.54-4.30µM with a good R2 of 0.9955 and a limit of detection of 0.17µM (0.03mgL-1) were achieved. The proposed system shows high tolerance to some possible interfering ions in natural water, surfactant, and other pesticides. The relative standard deviation (RSD) was 4.2% for 11 replicate measurements with the same electrode. The reproducibility for the preparation of 7 modified electrodes was 2.3% RSD. Recoveries of the analysis were obtained in the range of 82-106%. The developed system can be conveniently applied for analysis without pretreatment of the samples.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon nanotubes (CNTs); Differential pulse voltammetry; Nafion; Paraquat; Screen-printed carbon electrode (SPCE); Sequential injection analysis

Mesh:

Substances:

Year:  2017        PMID: 28501144     DOI: 10.1016/j.talanta.2017.03.073

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Highly Sensitive Fluorescent Probe for Detection of Paraquat Based on Nanocrystals.

Authors:  Zeinab Pourghobadi; Hadis Makanali; Hakimeh Zare
Journal:  J Fluoresc       Date:  2021-01-19       Impact factor: 2.217

Review 2.  Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes.

Authors:  Beatriz Pérez-Fernández; Agustín Costa-García; Alfredo de la Escosura- Muñiz
Journal:  Biosensors (Basel)       Date:  2020-04-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.