| Literature DB >> 28492733 |
Aifei Xu1, Zhong Fan1, Zhiyan Chen1, Yun Zhou1, Shaohua Liu1, Shijie Huang1, Xuequin Xu1, Congyun Long2, Weigang Wang1, Jing Zhu1, Xiaolan Li1, Chunping Xu3.
Abstract
A simple and sensitive method for simultaneous determination of furan and vinyl acetate (VA) in vapor phase of mainstream cigarette smoke with cold trap and gas chromatography-mass spectrometry (GC-MS) was developed. A Cambridge filter pad (CFP) was placed in front of the impingers of smoking machine to remove the particle phase from cigarette smoke. Furan and VA in vapor phase of mainstream cigarette smoke were collected in two impingers connected in series by filled with methanol at -78°C. The solutions were added with deuterium-labeled furan-d4 and VA-d6 as internal standards and analyzed by GC-MS. The results showed that the calibration curves for furan and VA were linear (r2 > 0.9995) over the studied concentration range. The intra- and inter-day precision values for furan and VA were <7.07% and <9.62%, respectively. The extraction recoveries of furan and VA were in the range of 94.5-97.7% and 92.3-94.9%, respectively. Moreover, the limits of detection for furan and VA were 0.028 µg mL-1 and 1.3 ng mL-1, respectively. The validated method has been successfully applied to determine the emissions of furan and VA in the vapor phase of mainstream cigarette smoke under International Organization for Standardization (ISO) and Canadian Intense (CI) smoking regimen.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28492733 DOI: 10.1590/0001-3765201720160230
Source DB: PubMed Journal: An Acad Bras Cienc ISSN: 0001-3765 Impact factor: 1.753