Update on Finger-Application-Type Noninvasive Continuous Hemodynamic Monitors (CNAP and ccNexfin): Physical Principles, Validation, and Clinical Use.

Eugene P Raggi1, Tetsuro Sakai1.   

Abstract

The CNAP HD Monitor (CNSystems, Graz, Austria) and the ccNexfin (The ClearSight System: Edwards Lifesciences Corporation, Irvine, CA) are continuous, noninvasive blood pressure monitors using a finger-application device. These devices show a promising ability to allow for rapid detection of hemodynamic derangement when compared with oscillometry. The accuracy and precision of these devices as blood pressure monitors has been evaluated when compared with intra-arterial catheters. Additionally, they can be used to measure beat-to-beat cardiac output (CO). As CO monitors, they are capable of trending changes in CO when compared with a transpulmonary thermodilution monitor. Difficulty with use in critically ill and awake patients has been encountered because of altered microvascular physiology and patient movement. The principles of operation and clinical validation of these devices are presented. The clinicians who are interested in using these devices in their clinical setting should be aware of the relatively large bias and CIs in the hemodynamic measurements.

Entities:  

Keywords:  accuracy and precision; blood pressure monitors; cardiac output; hemodynamics; sphygmomanometers

Mesh:

Year:  2017        PMID: 28490233     DOI: 10.1177/1089253217708620

Source DB:  PubMed          Journal:  Semin Cardiothorac Vasc Anesth        ISSN: 1089-2532


  5 in total

1.  Blood pressure measurement during cesarean delivery: Evaluation of a beat-to-beat noninvasive device (NexfinTM).

Authors:  Mathieu Bobet; Jona Joachim; Etienne Gayat; Agnès Bonnet; Kerstin Sievert; Carole Barnichon; Marc Fischler; Morgan Le Guen
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

2.  The hemodynamic stability of remimazolam compared with propofol in patients undergoing endoscopic submucosal dissection: A randomized trial.

Authors:  Yuwei Qiu; Wei Gu; Mingye Zhao; Yunyun Zhang; Jingxiang Wu
Journal:  Front Med (Lausanne)       Date:  2022-08-08

Review 3.  Blood pressure monitoring techniques in the natural state of multi-scenes: A review.

Authors:  Ziyi Liu; Congcong Zhou; Hongwei Wang; Yong He
Journal:  Front Med (Lausanne)       Date:  2022-08-26

4.  Non-invasive continuous blood pressure monitoring (ClearSight™ system) during shoulder surgery in the beach chair position: a prospective self-controlled study.

Authors:  Konrad Chachula; Florian Lieb; Florian Hess; Joellen Welter; Nicole Graf; Alexander Dullenkopf
Journal:  BMC Anesthesiol       Date:  2020-10-24       Impact factor: 2.217

5.  Four different methods of measuring cardiac index during cytoreductive surgery and hyperthermic intraperitoneal chemotherapy.

Authors:  Amon Heijne; Piet Krijtenburg; Andre Bremers; Gert Jan Scheffer; Ignacio Malagon; Cornelis Slagt
Journal:  Korean J Anesthesiol       Date:  2020-08-21