Literature DB >> 28489669

Rasch validation and comparison of Slovenian, Croatian, and Italian versions of the Mini-BESTest in patients with subacute stroke.

Nika Goljar1, Andrea Giordano, Tea Schnurrer Luke Vrbanić, Marko Rudolf, Ivanka Banicek-Sosa, Caterina Albensi, Helena Burger, Franco Franchignoni.   

Abstract

We aimed to verify by Rasch analysis whether the Mini-BESTest, a balance measure, confirms its main psychometric properties in patients with subacute stroke undergoing rehabilitation in three different countries (Slovenia, Croatia, and Italy), and to examine the stability of item hierarchy and difficulty across the three national versions through a differential item functioning analysis. We investigated 159 patients with subacute stroke consecutively admitted to three rehabilitation facilities after screening for an intensive, tailored rehabilitation program. Balance function was tested within 36 h from admission and after ∼25 days. As no differential item functioning was found between admission and discharge data or among countries, all data were pooled. Rasch criteria for the functioning of rating scale categories were fulfilled. In terms of internal construct validity, all items except item #14 (Cognitive Get Up & Go; infit value=1.42) showed an acceptable fit to the Rasch model. The patient ability-item difficulty matching was very good. Reliability indices were high. The Principal Component Analysis of standardized residuals confirmed the unidimensionality of the test. On the basis of the item calibration, raw scores of the Mini-BESTest were transformed into linear estimates of dynamic balance and six statistically detectable levels of balance ability were defined. Good psychometric features of the Mini-BESTest were confirmed. The three different national versions showed stability in item hierarchy, indicating equivalence of their cross-cultural adaptations. Problems with item #14 in these patients warrant further study.

Entities:  

Mesh:

Year:  2017        PMID: 28489669     DOI: 10.1097/MRR.0000000000000233

Source DB:  PubMed          Journal:  Int J Rehabil Res        ISSN: 0342-5282            Impact factor:   1.479


  2 in total

1.  The Frail'BESTest. An Adaptation of the "Balance Evaluation System Test" for Frail Older Adults. Description, Internal Consistency and Inter-Rater Reliability.

Authors:  A Kubicki; M Brika; L Coquisart; G Basile; D Laroche; F Mourey
Journal:  Clin Interv Aging       Date:  2020-07-30       Impact factor: 4.458

2.  Reliability and Validity of the Persian Version of the Mini-Balance Evaluation Systems Test in Patients with Stroke.

Authors:  Soofia Naghdi; Noureddin Nakhostin Ansari; Bijan Forogh; Maedeh Khalifeloo; Roshanak Honarpisheh; Amin Nakhostin-Ansari
Journal:  Neurol Ther       Date:  2020-08-14
  2 in total