Literature DB >> 28489547

A 172 $\mu$W Compressively Sampled Photoplethysmographic (PPG) Readout ASIC With Heart Rate Estimation Directly From Compressively Sampled Data.

Venkata Rajesh Pamula, Jose Manuel Valero-Sarmiento, Long Yan, Alper Bozkurt, Chris Van Hoof, Nick Van Helleputte, Refet Firat Yazicioglu, Marian Verhelst.   

Abstract

A compressive sampling (CS) photoplethysmographic (PPG) readout with embedded feature extraction to estimate heart rate (HR) directly from compressively sampled data is presented. It integrates a low-power analog front end together with a digital back end to perform feature extraction to estimate the average HR over a 4 s interval directly from compressively sampled PPG data. The application-specified integrated circuit (ASIC) supports uniform sampling mode (1x compression) as well as CS modes with compression ratios of 8x, 10x, and 30x. CS is performed through nonuniformly subsampling the PPG signal, while feature extraction is performed using least square spectral fitting through Lomb-Scargle periodogram. The ASIC consumes 172  μ W of power from a 1.2 V supply while reducing the relative LED driver power consumption by up to 30 times without significant loss of relevant information for accurate HR estimation.

Entities:  

Mesh:

Year:  2017        PMID: 28489547     DOI: 10.1109/TBCAS.2017.2661701

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  4 in total

1.  Wearable Photoplethysmography for Cardiovascular Monitoring.

Authors:  Peter H Charlton; Panicos A Kyriaco; Jonathan Mant; Vaidotas Marozas; Phil Chowienczyk; Jordi Alastruey
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-03-11       Impact factor: 10.961

2.  In Vivo Evaluation of a Subcutaneously Injectable Implant with a Low-Power Photoplethysmography ASIC for Animal Monitoring.

Authors:  Jose Manuel Valero-Sarmiento; Parvez Ahmmed; Alper Bozkurt
Journal:  Sensors (Basel)       Date:  2020-12-21       Impact factor: 3.576

3.  SPARE: A Spectral Peak Recovery Algorithm for PPG Signals Pulsewave Reconstruction in Multimodal Wearable Devices.

Authors:  Giulio Masinelli; Fabio Dell'Agnola; Adriana Arza Valdés; David Atienza
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

Review 4.  Triboelectric Effect Enabled Self-Powered, Point-of-Care Diagnostics: Opportunities for Developing ASSURED and REASSURED Devices.

Authors:  Navneet Soin; Sam J Fishlock; Colin Kelsey; Suzanne Smith
Journal:  Micromachines (Basel)       Date:  2021-03-22       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.