Literature DB >> 28483612

Stent-Graft Deployment Increases Aortic Stiffness in an Ex Vivo Porcine Model.

Hector W L de Beaufort1, Michele Conti2, Arnoud V Kamman1, Foeke J H Nauta1, Ettore Lanzarone3, Frans L Moll4, Joost A van Herwaarden4, Ferdinando Auricchio2, Santi Trimarchi5.   

Abstract

BACKGROUND: Aortic stiffness is an independent predictor of cardiovascular mortality. In this study, the effect of thoracic endovascular aortic repair (TEVAR) on aortic stiffness is investigated by measuring aortic pulse wave velocity (PWV) in an ex vivo porcine model.
METHODS: Fifteen fresh porcine thoracic aortas were connected to a benchtop pulsatile system. Intraluminal pressures were recorded in the ascending aorta and at the celiac trunk using a needle connected to a pressure sensor. The distance between the needles was divided by the time difference between the base of the pressure peaks to calculate aortic PWV at baseline and after stent-graft deployment and distal stent-graft extension.
RESULTS: Mean aortic PWV was 5.0 m/s at baseline. PWV increased by 4% after proximal stent-graft deployment (P = 0.09) and by 18% after stent-graft extension (P < 0.001). Pulse pressure in the nonstented ascending aorta increased by 11.0 ± 1.2 mm Hg after proximal stent-graft deployment (P < 0.001) and by 17.3 ± 1.5 mm Hg after stent-graft extension (P < 0.001). The increases in PWV and pulse pressure showed a positive linear correlation with the percentage of stent-graft coverage (P < 0.001 and P < 0.001).
CONCLUSIONS: In this experimental setup, aortic stiffness increased after stent-graft deployment, dependent on the percentage of the aorta that was covered by stent graft. These results show that TEVAR leads to significant changes in aortic hemodynamics, which merits evaluation in the clinical setting.
Copyright © 2017 Elsevier Inc. All rights reserved.

Mesh:

Year:  2017        PMID: 28483612     DOI: 10.1016/j.avsg.2017.04.024

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  4 in total

1.  Commentary: Measuring the impact of thoracic endovascular aortic repair on the heart.

Authors:  Jennifer Worsham; Abe DeAnda
Journal:  JTCVS Tech       Date:  2020-01-13

2.  Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model.

Authors:  Tomohiro Takano; Masumi Iwai-Takano; Yusuke Tsuboko; Yasuyuki Shiraishi; Tomoyuki Yambe; Takashi Igarashi; Hitoshi Yokoyama
Journal:  Sci Rep       Date:  2021-02-15       Impact factor: 4.379

3.  Influence of shape-memory stent grafts on local aortic compliance.

Authors:  J Concannon; K M Moerman; N Hynes; S Sultan; J P McGarry
Journal:  Biomech Model Mechanobiol       Date:  2021-09-19

4.  Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model.

Authors:  Hector W L de Beaufort; Margherita Coda; Michele Conti; Theodorus M J van Bakel; Foeke J H Nauta; Ettore Lanzarone; Frans L Moll; Joost A van Herwaarden; Ferdinando Auricchio; Santi Trimarchi
Journal:  PLoS One       Date:  2017-10-05       Impact factor: 3.240

  4 in total