Literature DB >> 28480603

A single-shot T2 mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.

Mei-Lan Chu1, Hing-Chiu Chang2, Koichi Oshio3, Nan-Kuei Chen1,4.   

Abstract

PURPOSE: To develop a high-speed T2 mapping protocol that is capable of accurately measuring T2 relaxation time constants from a single-shot acquisition. THEORY: A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals.
METHODS: The single-shot echo-split GRASE-based T2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated.
RESULTS: Using the developed single-shot T2 mapping protocol, quantitatively accurate T2 maps can be obtained with a short scan time (<0.2 seconds per slice).
CONCLUSION: Accurate T2 mapping with minimal signal contamination from CPMG high-order echo pathways can be achieved by the developed method that integrates single-shot echo-split GRASE acquisition and parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  GRASE; T2 mapping; echo-split GRASE; extended phase graph analysis; parametric-POCSMUSE

Mesh:

Year:  2017        PMID: 28480603     DOI: 10.1002/mrm.26696

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  2 in total

1.  Gradient- and spin-echo (GRASE) MR imaging: a long-existing technology that may find wide applications in modern era.

Authors:  Mei-Lan Chu; Cheng-Ping Chien; Wen-Chau Wu; Hsiao-Wen Chung
Journal:  Quant Imaging Med Surg       Date:  2019-09

2.  Improving the Accuracy, Quality, and Signal-To-Noise Ratio of MRI Parametric Mapping Using Rician Bias Correction and Parametric-Contrast-Matched Principal Component Analysis (PCM-PCA).

Authors:  Christa M Sonderer; Nan-Kuei Chen
Journal:  Yale J Biol Med       Date:  2018-09-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.