Vacuum level effects on knee contact force for unilateral transtibial amputees with elevated vacuum suspension.

Hang Xu1, Kasey Greenland2, Donald Bloswick2, Jie Zhao3, Andrew Merryweather4.   

Abstract

The elevated vacuum suspension system (EVSS) has demonstrated unique health benefits for amputees, but the effect of vacuum pressure values on knee contact force (KCF) is still unclear. The objective of this study was to investigate the effect of vacuum levels on KCF for unilateral transtibial amputees (UTA) using the EVSS. Three-dimensional gait was modeled for 9 UTA with five vacuum levels (0-20inHg [67.73kPa], 5inHg [16.93kPa] increments) and 9 non-amputees based on kinematic and ground reaction force data. The results showed that the vacuum level effects were significant for peak axial KCF, which had a relatively large value at 0 and 20inHg (67.73kPa). The intact limb exhibited a comparable peak axial KCF to the non-amputees at 15inHg (50.79kPa). At moderate vacuum levels (5inHg [16.93kPa] to 15inHg [50.79kPa]), co-contraction of quadriceps and hamstrings at peak axial KCF was similar for the intact limb, but was smaller for the residual limb comparing with the non-amputees. The intact limb showed a similar magnitude of quadriceps and hamstrings force at 15inHg (50.79kPa) to the non-amputees, but the muscle coordination patterns varied between the residual and intact limbs. These findings indicate that a proper vacuum level may partially compensate for the lack of ankle plantarflexor and reduce the knee loading. Of the tested vacuum levels, 15inHg (50.79kPa) appears most favorable, although additional analyses with more amputees are suggested to confirm these results prior to establishing clinical guidelines.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amputees; Biomechanics; Joint loading; Prosthesis; Vacuum level

Mesh:

Year:  2017        PMID: 28476209     DOI: 10.1016/j.jbiomech.2017.04.013

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  1 in total

1.  A Comparison of the Conventional PiG Marker Method Versus a Cluster-Based Model when recording Gait Kinematics in Trans-Tibial Prosthesis Users and the Implications for Future IMU Gait Analysis.

Authors:  Manunchaya Samala; Philip Rowe; Jutima Rattanakoch; Gary Guerra
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.