Literature DB >> 28475106

Flexible electronics-compatible non-enzymatic glucose sensing via transparent CuO nanowire networks on PET films.

Caroline Bell1, Abdullah Nammari, Pranay Uttamchandani, Amit Rai, Pujan Shah, Arden L Moore.   

Abstract

Diabetic individuals need simple, accurate, and cost effective means by which to independently assess their glucose levels in a non-invasive way. In this work, a sensor based on randomly oriented CuO nanowire networks supported by a polyethylene terephthalate thin film is evaluated as a flexible, transparent, non-enzymatic glucose sensing system analogous to those envisioned for future wearable diagnostic devices. The amperometric sensing characteristics of this type of device architecture are evaluated both before and after bending, with the system's glucose response, sensitivity, lower limit of detection, and effect of applied bias being experimentally determined. The obtained data shows that the sensor is capable of measuring changes in glucose levels within a physiologically relevant range (0-12 mM glucose) and at lower limits of detection (0.05 mM glucose at +0.6 V bias) consistent with patient tears and saliva. Unlike existing studies utilizing a conductive backing layer or macroscopic electrode setup, this sensor demonstrates a percolation network-like trend of current versus glucose concentration. In this implementation, controlling the architectural details of the CuO nanowire network could conceivably allow the sensor's sensitivity and optimal sensing range to be tuned. Overall, this work shows that integrating CuO nanowires into a sensor architecture compatible with transparent, flexible electronics is a promising avenue to realizing next generation wearable non-enzymatic glucose diagnostic devices.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28475106     DOI: 10.1088/1361-6528/aa7164

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  4 in total

Review 1.  Electrochemical nonenzymatic sensing of glucose using advanced nanomaterials.

Authors:  Keerthy Dhara; Debiprosad Roy Mahapatra
Journal:  Mikrochim Acta       Date:  2017-12-13       Impact factor: 5.833

Review 2.  Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids.

Authors:  Magnus Falk; Carolin Psotta; Stefan Cirovic; Sergey Shleev
Journal:  Sensors (Basel)       Date:  2020-11-07       Impact factor: 3.576

Review 3.  The Progress of Research into Flexible Sensors in the Field of Smart Wearables.

Authors:  Yunlei Yin; Cheng Guo; Hong Li; Hongying Yang; Fan Xiong; Dongyi Chen
Journal:  Sensors (Basel)       Date:  2022-07-06       Impact factor: 3.847

4.  Metal-Organic-Framework FeBDC-Derived Fe3O4 for Non-Enzymatic Electrochemical Detection of Glucose.

Authors:  Syauqi Abdurrahman Abrori; Ni Luh Wulan Septiani; Isa Anshori; Veinardi Suendo; Brian Yuliarto
Journal:  Sensors (Basel)       Date:  2020-08-29       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.