| Literature DB >> 2847224 |
H Roos1, W H Thomas, M Fitzek, A M Kellerer.
Abstract
The yield of his+ reversions in the Ames Salmonella tester strain TA2638 has been determined for 60Co gamma rays, 140 kV X rays, 5.4 keV characteristic X rays, 2.2 MeV protons, 3.1 MeV alpha particles, and 18 MeV/U Fe ions. Inactivation studies were performed with the same radiations. For both mutation and inactivation, the maximum effectiveness per unit absorbed dose was obtained for the characteristic X rays, which have a dose averaged linear energy transfer (LET) of roughly 10 keV/micron. The ratio of the effectiveness of this radiation to gamma rays was 2 for inactivation and about 1.4 for the his+ reversion. For both end points the effectiveness decreases substantially at high LET, i.e., for the alpha particles and the Fe ions. The composition of the bottom and the top agar was the one recommended by Maron and Ames [Mutat. Res. 113, 173-215 (1983)] for application in chemical mutagenicity tests. The experiments with the less penetrating radiations differed from the usual protocol by utilization of a technique of plating the bacteria on the surface of the top agar. As in an earlier study [Roos et al., Radiat. Res. 104, 102-108 (1985)] greatly enhanced yields of mutations, relative to the spontaneous reversion rate, were obtained in these experiments by performing the irradiations 6 h after plating, which differs from the conventional procedure to irradiate the bacteria shortly after plating.Entities:
Mesh:
Substances:
Year: 1988 PMID: 2847224
Source DB: PubMed Journal: Radiat Res ISSN: 0033-7587 Impact factor: 2.841