Literature DB >> 28468214

Efficacy and Safety of Willis Covered Stent for Treatment of Internal Carotid Artery Aneurysms.

Chunhai Tang1, Songtao Qi.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the clinical and short-term outcome of patients who underwent covered stent treatment for internal carotid artery aneurysms.
METHODS: Twelve cases patients with internal carotid artery aneurysms were treated with Willis covered stents during the period from December 2010 to January 2016. The guiding catheter was placed as high as possible to facilitate the delivery of the covered stent system.
RESULTS: Covered stent placement was successful in 11 of 12 case patients (91.6%), embolization was successful in 11 of 12 patients (91.6%), the treatment in 1 patient of 12 cavernous aneurysms patients was performed covered stents +ONYX + plastic coil embolization, and the other was used Willis covered stents. The results indicated that only 1 of 12 patients underwent postoperative massive cerebral infarction, but was successfully rescued. The angiographic following-up of patients using covered stent suggested that 12 cases patients were complete occlusion and the parent artery patency. Clinical follow-up results also demonstrated that clinical neurologic symptoms fully recovered in 11 of 12 cases patients, another case improved and were not aggravated in any patient before discharge and had aggravated symptoms.
CONCLUSION: Willis covered stents are effective for treatment of internal carotid artery aneurysms with good safety and short-term outcomes.

Entities:  

Mesh:

Year:  2017        PMID: 28468214     DOI: 10.1097/SCS.0000000000003565

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  3 in total

1.  Recurrence of an internal carotid artery aneurysm after complete exclusion by a Willis covered stent.

Authors:  Zhongbin Tian; Shiqing Mu; Wenqiang Li; Wei Zhu; Ying Zhang; Xinjian Yang; Jian Liu
Journal:  Interv Neuroradiol       Date:  2019-06-03       Impact factor: 1.610

2.  Pipeline Embolization Device for Salvage Treatment of a Willis Covered Stent Prolapse Into the Aneurysmal Sac.

Authors:  Zeng-Bao Wu; Sheng Wang; Li-Gang Song; Xin-Jian Yang; Shi-Qing Mu
Journal:  Front Neurol       Date:  2019-10-17       Impact factor: 4.003

3.  Willis Covered Stent for Treating Intracranial Pseudoaneurysms of the Internal Carotid Artery: A Multi-Institutional Study.

Authors:  Dan Lu; Tao Ma; Gemin Zhu; Tao Zhang; Naibing Wang; Hui Lei; Jing Sui; Zhiguo Wang; Shiming He; Lei Chen; Jianping Deng
Journal:  Neuropsychiatr Dis Treat       Date:  2022-01-29       Impact factor: 2.570

  3 in total