Literature DB >> 28467258

Effect of Endocrown Pulp Chamber Extension Depth on Molar Fracture Resistance.

A Hayes, N Duvall, M Wajdowicz, H Roberts.   

Abstract

PURPOSE: The purpose of this study was to evaluate the effect of endocrown pulp chamber extension on mandibular molar fracture resistance. METHODS AND MATERIALS: A total of 36 recently extracted mandibular third molars of approximate equal size were sectioned at the facial lingual height of contour followed by endodontic access into the pulp chamber. The specimens were then randomly divided into three groups (n=12) and pulpal and root canal contents removed. Pulp chamber floors were established at 2, 3, and 4 mm from the occlusal table using a three-step etch-and-rinse adhesive and a flowable resin composite. The prepared specimens were then embedded in auto-polymerizing denture base resin with surface area available for adhesive bonding determined using a digital recording microscope. Specimens were restored using a standardized template with a chairside computer-aided design/computer-aided manufacturing unit with the endocrown milled from a lithium disilicate glass-ceramic material. Restoration parameters of occlusal table anatomy and thickness were standardized with the only parameter difference being the pulp chamber extension depth. The endocrown restorations were luted with a self-adhesive resin luting agent and tested to failure after 24 hours on a universal testing machine, with force applied to the facial cusps at a 45° angle to the long axis of the tooth. The failure load was converted into stress for each specimen using the available surface area for bonding. Mean failure load and stress among the three groups was first subjected to the Shapiro-Wilk and Bartlett tests and then analyzed with an analysis of variance with the Tukey post hoc test at a 95% confidence level (p=0.05).
RESULTS: The 2- and 4-mm chamber extension groups demonstrated the highest fracture resistance stress, with the 3-mm group similar to the 2-mm group. The 3- and 4-mm chamber extension group specimens demonstrated nearly universal catastrophic tooth fracture, whereas half the 2-mm chamber extension group displayed nonrestorable root fractures.
CONCLUSIONS: Under the conditions of this study, mandibular molars restored with the endocrown technique with 2- and 4-mm pulp chamber extensions displayed greater tooth fracture resistance force as well as stress. All groups demonstrated a high number of catastrophic fractures, but these results may not be clinically significant because the fracture force results are higher than normal reported values of masticatory function.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28467258     DOI: 10.2341/16-097-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

1.  The fracture strength of endocrowns manufactured from different hybrid blocks under axial and lateral forces.

Authors:  Duygu Hazal Acar; Elif Kalyoncuoğlu
Journal:  Clin Oral Investig       Date:  2020-08-19       Impact factor: 3.573

2.  [Effects of the resin base and retention depth on fracture resistance of molars restored with nano-ceramic endocrowns].

Authors:  Z Li; Y X Xu; X D Bao; X Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

3.  Role of Computed Tomography Scan in Dental Trauma: A Cross-Sectional Study.

Authors:  Feng Li; Jun Li; Deming Zhang; Feng Wu
Journal:  Dose Response       Date:  2018-08-23       Impact factor: 2.658

4.  The impact of restorative material and ceramic thickness on CAD\CAM endocrowns.

Authors:  João-Paulo-Mendes Tribst; Amanda-Maria-de Oliveira Dal Piva; Camila-Ferreira-Leite Madruga; Marcia-Carneiro Valera; Eduardo Bresciani; Marco-Antonio Bottino; Renata-Marques de Melo
Journal:  J Clin Exp Dent       Date:  2019-11-01

5.  Resistance fracture of minimally prepared endocrowns made by three types of restorative materials: a 3D finite element analysis.

Authors:  Qingzhen Meng; Yuejiao Zhang; Danlu Chi; Qimei Gong; Zhongchun Tong
Journal:  J Mater Sci Mater Med       Date:  2021-10-30       Impact factor: 3.896

6.  Comparison of retention and fracture load of endocrowns made from zirconia and zirconium lithium silicate after aging: an in vitro study.

Authors:  Majid Sahebi; Safoura Ghodsi; Parsia Berahman; Amirhesam Amini; Somayeh Zeighami
Journal:  BMC Oral Health       Date:  2022-02-16       Impact factor: 2.757

7.  Fracture resistance, failure mode and stress concentration in a modified endocrown design.

Authors:  Wiam El Ghoul; Mutlu Özcan; Joao Paulo Mendes Tribst; Ziad Salameh
Journal:  Biomater Investig Dent       Date:  2020-08-07

8.  Biomechanical behavior of endocrowns vs fiber post-core-crown vs cast post-core-crown for the restoration of maxillary central incisors with 1 mm and 2 mm ferrule height: A 3D static linear finite element analysis.

Authors:  Xixi Li; Ting Kang; Danting Zhan; Jing Xie; Ling Guo
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.