The effect of endorectal balloon on anorectal dose during postoperative volumetric arc radiotherapy of prostate cancer.

Tino Streller1, Urs Rusch1, Maria D Herraiz Lablanca1, Ira Minneken1, Yousef Najafi1, Binaya Shrestha1, Susanne Oertel1, Oliver Riesterer2.   

Abstract

PURPOSE: To evaluate the impact of endorectal balloon (ERB) on anorectal dose during postoperative VMAT of prostate cancer.
METHODS: In ten patients referred for salvage radiotherapy CTs were obtained without ERB and with air-filled ERB of 50ml and 100ml. CTs were repeated weekly (4-6 control CTs) and registered to the respective planning CT. For each planning CT, a VMAT plan was made with defined anorectal dose constraints and propagated on the respective control CTs. The dose volumes V40Gy, V60Gy and V65Gy of the rectal and anal wall (Rwall and Awall, respectively) and the ERB position were obtained from each plan.
RESULTS: In plans with ERB, the mean Rwall dose volumes V40Gy, V60Gy and V65Gy were higher by 8%, 5% and 2% (ERB 50ml) and 2%, 3% and 3% (ERB 100ml) in comparison to plans without ERB. The respective Awall dose volume differences were 2%, 0%, -1% (ERB 50ml), and -3%, -2%, -2% (ERB 100ml). The dose volume variability of the Rwall was comparable with and without ERB, but was slightly reduced by ERB for the Awall. The mean ERB position variability was >2mm in anterior-posterior and inferior-superior directions.
CONCLUSION: The use of ERB during post-operative VMAT has no advantages for anorectal dose.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anorectal dose; Endorectal balloon; Post-prostatectomy; VMAT

Mesh:

Year:  2017        PMID: 28464996     DOI: 10.1016/j.radonc.2017.04.014

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  Dosimetric and radiobiological comparison in different dose calculation grid sizes between Acuros XB and anisotropic analytical algorithm for prostate VMAT.

Authors:  Kyeong-Hyeon Kim; Jin-Beom Chung; Tae Suk Suh; Sang-Won Kang; Seong-Hee Kang; Keun-Yong Eom; Changhoon Song; In-Ah Kim; Jae-Sung Kim
Journal:  PLoS One       Date:  2018-11-12       Impact factor: 3.240

2.  Application of rectal retractor for postprostatectomy salvage radiotherapy of prostate cancer: A case report and literature review.

Authors:  Hamed Ghaffari; Mahdieh Afkhami Ardekani; Seyed Hadi Molana; Mohammad Haghparast; Mastaneh Sanei; Seied Rabi Mahdavi; Bahram Mofid; Aram Rostami
Journal:  Clin Case Rep       Date:  2019-09-27

3.  Clinical effects of rectal retractor application in prostate cancer radiotherapy.

Authors:  Amir Mohammad Arefpour; Mahshid Abbasi; Seied Rabi Mahdavi; Mahdiyeh Shafieesabet; Pedram Fadavi
Journal:  Med J Islam Repub Iran       Date:  2021-05-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.