Literature DB >> 28463763

A novel and sensitive carbon paste electrode with clinoptilolite nano-particles containing hexadecyltrimethyl ammonium surfactant and dithizone for the voltammetric determination of Sn(II).

Azin Niknezhadi1, Alireza Nezamzadeh-Ejhieh2.   

Abstract

Clinoptilolite nano-particles (CNP) were modified by hexadecyltrimethyl ammonium bromide surfactant (HDTMA) and dithizone (DZ). The modified zeolite was then used for the modification of carbon paste electrode (CPE). The resulted CNP-HDTMA-DZ-CPE was finally used for the voltammetric determination of Sn(II) in aqueous solution. The raw and modified CNP was characterized by SEM-EDX, BET, TG-DTG and FTIR techniques. The best voltammetric response was obtained in 0.1molL-1 NaNO3+HCl at pH 2.2 as supporting electrolyte. The electrode showed a linear response in the concentration range of 1×10-8 to 1×10-2molL-1Sn(II) with LOD about 9×10-9molL-1Sn(II). The electrode showed good selectivity and applicability for the determination of Sn(II) in real samples such as river water, an steel company wastewater, tomato paste and a canned tuna fish.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Clinoptilolite nanoparticles; Dithizone; Sn(II); Surfactant modified zeolite; Zeolite modified carbon paste electrodes

Mesh:

Substances:

Year:  2017        PMID: 28463763     DOI: 10.1016/j.jcis.2017.04.068

Source DB:  PubMed          Journal:  J Colloid Interface Sci        ISSN: 0021-9797            Impact factor:   8.128


  4 in total

1.  EDTA-functionalized clinoptilolite nanoparticles as an effective adsorbent for Pb(II) removal.

Authors:  Farahnaz Eshraghi; Alireza Nezamzadeh-Ejhieh
Journal:  Environ Sci Pollut Res Int       Date:  2018-03-08       Impact factor: 4.223

Review 2.  Developments and applications of nanomaterial-based carbon paste electrodes.

Authors:  Somayeh Tajik; Hadi Beitollahi; Fariba Garkani Nejad; Mohadeseh Safaei; Kaiqiang Zhang; Quyet Van Le; Rajender S Varma; Ho Won Jang; Mohammadreza Shokouhimehr
Journal:  RSC Adv       Date:  2020-06-04       Impact factor: 4.036

3.  Ultrasensitive determination of mercury ions using a glassy carbon electrode modified with nanocomposites consisting of conductive polymer and amino-functionalized graphene quantum dots.

Authors:  Bowen Tian; Yanxia Kou; Xiangmei Jiang; Jiajia Lu; Yuanyuan Xue; Meijuan Wang; Liang Tan
Journal:  Mikrochim Acta       Date:  2020-03-09       Impact factor: 5.833

4.  Biopolymer-Modified Carbon Paste Electrode for the Electrochemical Detection of Pb(II) in Water.

Authors:  Ousama Ifguis; Abdelaziz Moutcine; Charaf Laghlimi; Younes Ziat; Rachid Bouhdadi; Abdelilah Chtaini; Amine Moubarik; Mohamed Mbarki
Journal:  J Anal Methods Chem       Date:  2022-01-31       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.