Literature DB >> 28463190

Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator.

Charles Tremblay-Darveau, Avinoam Bar-Zion, Ross Williams, Paul S Sheeran, Laurent Milot, Thanasis Loupas, Dan Adam, Matthew Bruce, Peter N Burns.   

Abstract

While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the noise due to the time-gain compensation and the received beamforming aperture ultimately limits sensitivity. In this paper, we demonstrate that the performance of power Doppler imaging can be improved by leveraging the higher lags of the autocorrelation [e.g., R(1), R(2),…] instead of the signal power (R(0)). As noise is completely uncorrelated from pulse-to-pulse while the flow signal remains correlated significantly longer, weak signals just above the noise floor can be made visible through the reduction of the noise floor. Finally, as coherence decreases proportionally with respect to velocity, we demonstrate how signal coherence can be targeted to separate flows of different velocities. For instance, we show how long-time-range coherence of microbubble contrast-enhanced flow specifically isolates slow capillary perfusion (as opposed to conduit flow).

Mesh:

Year:  2017        PMID: 28463190     DOI: 10.1109/TMI.2017.2699672

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Adaptive and Robust Vessel Quantification in Contrast-Free Ultrafast Ultrasound Microvessel Imaging.

Authors:  Shanshan Tang; Chengwu Huang; Ping Gong; U-Wai Lok; Chenyun Zhou; Lulu Yang; Kate M Knoll; Kathryn A Robinson; Shannon P Sheedy; Joel G Fletcher; David H Bruining; John M Knudsen; Shigao Chen
Journal:  Ultrasound Med Biol       Date:  2022-07-23       Impact factor: 3.694

2.  Blood Flow Imaging in the Neonatal Brain Using Angular Coherence Power Doppler.

Authors:  Marko Jakovljevic; Byung Chul Yoon; Lotfi Abou-Elkacem; Dongwoon Hyun; You Li; Erika Rubesova; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

3.  Simultaneous Noise Suppression and Incoherent Artifact Reduction in Ultrafast Ultrasound Vascular Imaging.

Authors:  Chengwu Huang; Pengfei Song; Joshua D Trzasko; Ping Gong; U-Wai Lok; Shanshan Tang; Armando Manduca; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-05-25       Impact factor: 3.267

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.