Literature DB >> 28461047

Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant.

Nadja Rohr1, Stefan Brunner2, Sabrina Märtin3, Jens Fischer4.   

Abstract

STATEMENT OF PROBLEM: The best procedure for cementing a restoration to zirconia implants has not yet been established.
PURPOSE: The purpose of this in vitro study was to measure the retention of polymer-infiltrated ceramic crowns to zirconia 1-piece implants using a wide range of cements. The effect of ceramic primer treatment on the retention force was also recorded. The retention results were correlated with the shear bond strength of the cement to zirconia and the indirect tensile strength of the cements to better understand the retention mechanism.
MATERIAL AND METHODS: The retention test was performed using 100 polymer-infiltrated ceramic crowns (Vita Enamic) and zirconia implants (ceramic.implant CI) The crowns were cemented with either interim cement (Harvard Implant semipermanent, Temp Bond), glass-ionomer cement (Ketac Cem), self-adhesive cement (Perma Cem 2.0, RelyX Unicem Automix 2, Panavia SA), or adhesive cement (Multilink Implant, Multilink Automix, Vita Adiva F-Cem, RelyX Ultimate, Panavia F 2.0, Panavia V5 or Panavia 21) (n=5). Additionally ceramic primer was applied on the intaglio crown surface and implant abutment before cementation for all adhesive cements (Multilink Implant, Multilink Automix: Monobond plus; RelyX Ultimate Scotchbond Universal; Vita Adiva F-Cem: Vita Adiva Zr-Prime; Panavia F2.0, Panavia V5: Clearfil Ceramic Primer) and 1 self-adhesive cement containing 10-methacryloyloxydecyl dihydrogen phosphate (MDP) (Panavia SA: Clearfil Ceramic Primer). Crown debond fracture patterns were recorded. Shear bond strength was determined for the respective cement groups to polished zirconia (n=6). The diametral tensile strength of the cements was measured (n=10). Statistical analysis was performed using 1-way or 2-way analysis of variance followed by the Fisher LSD test (α=.05) within each test parameter.
RESULTS: Adhesive and self-adhesive resin cements had shear bond strength values of 0.0 to 5.3 MPa and revealed similar retention forces. Cements containing MDP demonstrated shear bond strength values above 5.3 MPa and displayed increased retention. The highest retention values were recorded for Panavia F 2.0 (318 ±28 N) and Panavia 21 (605 ±82 N). All other adhesive and self-adhesive resin cements attained retention values between 222 ±16 N (Multilink Automix) and 270 ±26 N (Panavia SA), which were significantly higher (P<.05) than glass-ionomer (Ketac Cem: 196 ±34 N) or interim cement (Harvard Implant semipermanent: 43 ±6 N, Temp Bond: 127 ±13 N). Application of manufacturer-specific ceramic primer increased crown retention significantly only for Panavia SA.
CONCLUSIONS: Products containing MDP provided a high chemical bond to zirconia. Self-adhesive and adhesive resin cements with low chemical bonding capabilities to zirconia provided retention force values within a small range (220 to 290 N).
Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28461047     DOI: 10.1016/j.prosdent.2017.02.002

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Retention strength of monolithic zirconia crowns cemented with different primer-cement systems.

Authors:  Mohamed Shokry; Walid Al-Zordk; Mohamed Ghazy
Journal:  BMC Oral Health       Date:  2022-05-19       Impact factor: 3.747

2.  Retention of different CAD/CAM endocrowns bonded to severely damaged endodontically treated teeth: An in vitro study.

Authors:  Yasmin Elashmawy; Moustafa Aboushelib; Waleed Elshahawy
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

3.  The Effect of a 10-MDP-Based Dentin Adhesive as Alternative for Bonding to Implant Abutment Materials.

Authors:  Paula C K Carvalho; Cláudia C M S Almeida; Rodrigo O A Souza; Rubens Nisie Tango
Journal:  Materials (Basel)       Date:  2022-08-08       Impact factor: 3.748

Review 4.  Clinical outcomes of all-ceramic single crowns and fixed dental prostheses supported by ceramic implants: A systematic review and meta-analyses.

Authors:  Frank Akito Spitznagel; Marc Balmer; Daniel B Wiedemeier; Ronald Ernst Jung; Petra Christine Gierthmuehlen
Journal:  Clin Oral Implants Res       Date:  2021-11-05       Impact factor: 5.021

5.  A comprehensive in vitro study on the performance of two different strategies to simplify adhesive bonding.

Authors:  Nadja Rohr; Sabrina Märtin; Nicola U Zitzmann; Jens Fischer
Journal:  J Esthet Restor Dent       Date:  2022-03-19       Impact factor: 3.040

6.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

7.  Effect of Luting Cement and Convergence Angle of the Preparation on the Internal Fit of Zirconia Restorations.

Authors:  Andrés Sánchez-Monescillo; Carlos González-Serrano; José González-Serrano; João Malta Barbosa; Carlos López-Suárez; Sillas Duarte
Journal:  Materials (Basel)       Date:  2021-12-18       Impact factor: 3.623

  7 in total