Comparative Study for Alignment of Extramedullary Guides versus Portable, Accelerometer-Based Navigation in Total Knee Arthroplasty.

Kazu Matsumoto1, Hiroyasu Ogawa1, Masashi Fukuta2, Nobuyuki Mori3, Haruhiko Akiyama1.   

Abstract

The use of portable, accelerometer-based navigation (PN) devices for positioning of the components of total knee arthroplasty (TKA) is emerging as an alternative to standard extramedullary (EM) systems, which was needed to the image intensifier. The aim of our study was to compare the accuracy of component positioning in TKA using an EM and PN systems. Data from 100 consecutive primary TKAs, performed by multiple surgeons in 87 patients between October 2010 and June 2015, were analyzed. Coronal and sagittal plane alignments of the TKA components, relative to the mechanical axis of the limb, were evaluated by radiography. The mean postoperative coronal alignment angle of the femoral (α) and tibial (β) components was comparable between the groups (α: PN, 89.9 ± 2.2 degrees; EM, 89.9 ± 1.6 degrees and β: PN, 90.1 ± 1.4 degrees; EM, 89.6 ± 1.3 degrees). Groups were also comparable with regard to mean postoperative sagittal alignment angle of the femoral and tibial components (γ: PN, 2.3 ± 3.3 degrees; EM, 1.8 ± 1.7 degrees and σ: PN, 89.7 ± 2.5 degrees; EM, 90.1 ± 1.3 degrees). The incidence rate of a component malalignment > 3 degrees in the coronal and sagittal planes of the mechanical axis of the knee was comparable between the groups. In conclusion, the coronal and sagittal alignments for the femoral components was less accurate compared with tibial component alignment, especially in the PN group, and the sagittal alignment of the femoral component was less accurate than coronal alignment for both groups. Both the PN and EM systems provide satisfactory coronal and sagittal component alignments in TKA. Further technical improvement of the PN system could further improve its application for accurate component implantation in TKAs. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2017        PMID: 28460410     DOI: 10.1055/s-0037-1602133

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  4 in total

1.  CORR Insights®: Does Accelerometer-based Navigation Have Any Clinical Benefit Compared with Conventional TKA? A Systematic Review.

Authors:  Jean-Noel A Argenson
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

2.  Surgical procedures for the prevention of extension-flexion gap imbalance in total knee arthroplasty.

Authors:  Koki Kato; Hiroyasu Ogawa; Kazu Matsumoto; Haruhiko Akiyama
Journal:  J Orthop       Date:  2021-05-14

3.  Total knee arthroplasty in the next decade: is navigation necessary?

Authors:  Graham S Goh; Ming Han Lincoln Liow
Journal:  Ann Transl Med       Date:  2020-06

4.  Comparative Analysis of Radiological Evaluation and Early Functional Outcomes of Total Knee Arthroplasty Using an Accelerometer-Based Handheld Navigation System and Conventional Instrumentation: A Prospective Study.

Authors:  Nuthan Jagadeesh; Hiranya Kumar; Varma Sarparaju; Vishwanath Shivalingappa
Journal:  Cureus       Date:  2022-01-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.