Literature DB >> 28459298

Reliability of Power Settings of the Wahoo KICKR Power Trainer After 60 Hours of Use.

Emma K Zadow, Cecilia M Kitic, Sam S X Wu, James W Fell.   

Abstract

PURPOSE: To assess the reliability of power-output measurements of a Wahoo KICKR Power Trainer (KICKR) on 2 separate occasions separated by 14 mo of regular use (∼1 h/wk).
METHODS: Using the KICKR to set power outputs, powers of 100-600 W in increments of 50 W were assessed at cadences of 80, 90, and 100 rpm that were controlled and validated by a dynamic calibration rig.
RESULTS: A small ratio bias of 1.002 (95% limits of agreement [LoA] 0.992-1.011) was observed over 100-600 W at 80-100 rpm between trials 1 and 2. Similar ratio biases with acceptable limits of agreement were observed at 80 rpm (1.003 [95% LoA 0.987-1.018]), 90 rpm (1.000 [0.996-1.005]), and 100 rpm (1.002 [0.997-1.007]). The intraclass correlation coefficient with 95% confidence interval (CI) for mean power between trials was 1.00 (95% CI 1.00-1.00) with a typical error (TE) of 3.1 W and 1.6% observed between trials 1 and 2.
CONCLUSION: When assessed at 2 separate time points 14 mo apart, the KICKR has acceptable reliability for combined power outputs of 100-600 W at 80-100 rpm, reporting overall small ratio biases with acceptable LoA and low TE. Coaches and sport scientists should feel confident in the power output measured by the KICKR over an extended period of time when performing laboratory training and performance assessments.

Entities:  

Keywords:  ergometry; reproducibility; training

Mesh:

Year:  2018        PMID: 28459298     DOI: 10.1123/ijspp.2016-0732

Source DB:  PubMed          Journal:  Int J Sports Physiol Perform        ISSN: 1555-0265            Impact factor:   4.010


  4 in total

1.  Validity and Reliability of the PowerTap P1 Pedals Power Meter.

Authors:  Jesús G Pallarés; José Ramón Lillo-Bevia
Journal:  J Sports Sci Med       Date:  2018-05-14       Impact factor: 2.988

2.  Are the Assioma Favero Power Meter Pedals a Reliable Tool for Monitoring Cycling Power Output?

Authors:  Víctor Rodríguez-Rielves; José Ramón Lillo-Beviá; Ángel Buendía-Romero; Alejandro Martínez-Cava; Alejandro Hernández-Belmonte; Javier Courel-Ibáñez; Jesús G Pallarés
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

Review 3.  Caveats and Recommendations to Assess the Validity and Reliability of Cycling Power Meters: A Systematic Scoping Review.

Authors:  Anthony Bouillod; Georges Soto-Romero; Frederic Grappe; William Bertucci; Emmanuel Brunet; Johan Cassirame
Journal:  Sensors (Basel)       Date:  2022-01-05       Impact factor: 3.576

4.  A three-minute all-out test performed in a remote setting does not provide a valid estimate of the maximum metabolic steady state.

Authors:  Ed Maunder; Jeffrey A Rothschild; Andrius Ramonas; Matthieu Delcourt; Andrew E Kilding
Journal:  Eur J Appl Physiol       Date:  2022-08-10       Impact factor: 3.346

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.